The DOI matches its Crossref record.
Second-harmonic microscopy of biological tissue
Abstract
We present the first reported optical second-harmonic microscope images of a biological sample—rattail tendon—and discuss, also for the first time, the need to distinguish between coherent and incoherent second-harmonic imaging. Our data show that the currently unexplained macroscopic polar order of this classic representative of connective tissue is due both to a coherent network containing a large number of fine, polar, filamentlike structures that permeate the entire tendon volume and to a small number of intensely polar surface patches.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Nonlinear magic: multiphoton microscopy in the biosciences
Zipfel, W. R., Williams, R. M., & Webb, W. W. (2003) · Nature Biotechnology · doi:10.1038/nbt899 · Cited by 3,893
Surface properties probed by second-harmonic and sum-frequency generation
Shen, Y. R. (1989) · Nature · doi:10.1038/337519a0 · Cited by 2,350
Zipfel, W. R., Williams, R. M., Christie, R., Nikitin, A. Y., Hyman, B. T., & Webb, W. W. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0832308100 · Cited by 1,676
Interpreting Second-Harmonic Generation Images of Collagen I Fibrils
Williams, R. M., Zipfel, W. R., & Webb, W. W. (2005) · Biophysical Journal · doi:10.1529/biophysj.104.047308 · Cited by 840
Doubly resonant χ (2) nonlinear photonic crystal cavity based on a bound state in the continuum
Minkov, M., Gerace, D., & Fan, S. (2019) · Optica · doi:10.1364/optica.6.001039 · Cited by 134
Metadata
- Authors
- Freund, I., & Deutsch, M.
- Venue
- Optics Letters
- Publisher
- Optica Publishing Group
- Published
- 1986-02-01
- Volume
- 11
- Issue
- 2
- Pages
- 94
- ISSN
- 0146-9592 (ISSN-L)
- 1539-4794
- OpenAlex
- W2166006670
- Cited by
- 239
- References
- 0
- FWCI
- 1.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Second-harmonic microscopy of biological tissue. https://app.cochat.ai/papers/10.1364/ol.11.000094
- The paper
- Freund, I., & Deutsch, M. (1986). Second-harmonic microscopy of biological tissue. Optics Letters. https://doi.org/10.1364/ol.11.000094
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.