CoChat

Measurement of the Pancharatnam phase for a light beam

Chyba, T. H., Simon, R., Wang, L. J., Mandel, L. · 1988 · Optics Letters
Cited by 127

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

By using a Michelson interferometer arrangement, we have measured the phase shift (the Pancharatnam phase) experienced by a light beam whose state of polarization is made to follow, by successive unitary transformations, a closed circuit on the Poincaré sphere. We confirm that the phase shift equals half of the solid angle subtended by the closed circuit at the center of the sphere. This phase is closely related to the topological Berry phase.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1364/ol.13.000562

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 127

Metadata

Authors
Chyba, T. H., Simon, R., Wang, L. J., & Mandel, L.
Venue
Optics Letters
Published
1988-07-01
Volume
13
Issue
7
Pages
562
ISSN
  • 0146-9592 (ISSN-L)
  • 1539-4794
OpenAlex
W2016539577
Cited by
127
References
7
FWCI
4.26
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Measurement of the Pancharatnam phase for a light beam. https://app.cochat.ai/papers/10.1364/ol.13.000562
The paper
Chyba, T. H., Simon, R., Wang, L. J., & Mandel, L. (1988). Measurement of the Pancharatnam phase for a light beam. Optics Letters. https://doi.org/10.1364/ol.13.000562

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.