Distortion of femtosecond laser pulses in lenses
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Large temporal front distortion of femtosecond pulses occurs in lenses having chromatic aberration. The effect is due to the difference between the phase and group velocities. Equations describing the pulse-front delay in singlet lenses, achromats, and compound lenses are presented. The pulse-front delay is several orders of magnitude larger than the broadening caused by group-velocity dispersion in the lens material. Delays occurring in Fresnel-type zone plates are also described.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Interspecimen Comparison of the Refractive Index of Fused Silica*,†
Malitson, I. H. (1965) · Journal of the Optical Society of America · doi:10.1364/josa.55.001205 · Cited by 4,216
Optical pulse compression with diffraction gratings
Treacy, E. (1969) · IEEE Journal of Quantum Electronics · doi:10.1109/jqe.1969.1076303 · Cited by 1,363
Negative dispersion using pairs of prisms
Fork, R. L., Martinez, O. E., & Gordon, J. P. (1984) · Optics Letters · doi:10.1364/ol.9.000150 · Cited by 944
Negative group-velocity dispersion using refraction
Martinez, O. E., Gordon, J. P., & Fork, R. L. (1984) · Journal of the Optical Society of America A · doi:10.1364/josaa.1.001003 · Cited by 358
Sagnac effect in fiber gyroscopes
Arditty, H. J., & Lefèvre, H. C. (1981) · Optics Letters · doi:10.1364/ol.6.000401 · Cited by 220
Distortion of Femtosecond Laser Pulses in Lenses and Lens Systems
Bor, Z. (1988) · Journal of Modern Optics · doi:10.1080/713822325 · Cited by 210
Self-citationBor, Z., & Rácz, B. (1985) · Optics Communications · doi:10.1016/0030-4018(85)90284-6 · Cited by 175
Self-citationPrism-pair dispersive delay lines in optical pulse compression
Kafka, J. D., & Baer, T. M. (1987) · Optics Letters · doi:10.1364/ol.12.000401 · Cited by 90
Cited by
Space–time characterization of ultra-intense femtosecond laser beams
Pariente, G., Gallet, V., Borot, A., Gobert, O., & Quéré, F. (2016) · Nature Photonics · doi:10.1038/nphoton.2016.140 · Cited by 228
Coherent soft-x-ray generation by the harmonics of an ultrahigh-power KrF laser
Sarukura, N., Hata, K., Adachi, T., Nodomi, R., Watanabe, M., & Watanabe, S. (1991) · Physical Review A · doi:10.1103/physreva.43.1669 · Cited by 187
Noninvasive porosity measurement of biconvex tablets using terahertz pulses
Bawuah, P., Ervasti, T., Tan, N., Zeitler, J. A., Ketolainen, J., & Peiponen, K.-E. (2016) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2016.06.023 · Cited by 29
Metadata
- Authors
- Bor, Z.
- Venue
- Optics Letters
- Publisher
- Optica Publishing Group
- Published
- 1989-01-15
- Volume
- 14
- Issue
- 2
- Pages
- 119
- ISSN
- 0146-9592 (ISSN-L)
- 1539-4794
- OpenAlex
- W1995857840
- Cited by
- 211
- References
- 8
- FWCI
- 5.01
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.