The DOI matches its Crossref record.
Pulse-length dependence of cellular response to intense near-infrared laser pulses in multiphoton microscopes
Abstract
The influence of the pulse length, tau , of ultrashort laser pulses at 780 and 920 nm on cell vitality and cellular reproduction has been studied. A total of 2400 nonlabeled cells were exposed to a highly focused scanning beam from a mode-locked 80-MHz Ti:sapphire laser with 60-micros pixel dwell time. For the same pulse energy, destructive effects were more pronounced for shorter pulses. The damage behavior was found to follow approximately a P(2)/tau dependence (P , mean power), indicating that cell destruction is likely based on a two-photon excitation process rather than a one- or a three-photon event. Therefore, femtosecond as well as picosecond pulses provide approximately the same relative optical window for safe two-photon fluorescence microscopy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Fluorescence microscopy with diffraction resolution barrier broken by stimulated emission
Klar, T. A., Jakobs, S., Dyba, M., Egner, A., & Hell, S. W. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.97.15.8206 · Cited by 1,869
Multiphoton microscopy in life sciences
König, K. (2000) · Journal of Microscopy · doi:10.1046/j.1365-2818.2000.00738.x · Cited by 1,265
Self-citationPrinciples of two-photon excitation microscopy and its applications to neuroscience
Svoboda, K., & Yasuda, R. (2006) · Neuron · doi:10.1016/j.neuron.2006.05.019 · Cited by 1,027
Phototoxicity in live fluorescence microscopy, and how to avoid it
Icha, J., Weber, M., Waters, J. C., & Norden, C. (2017) · BioEssays · doi:10.1002/bies.201700003 · Cited by 622
Highly Nonlinear Photodamage in Two-Photon Fluorescence Microscopy
Hopt, A., & Neher, E. (2001) · Biophysical Journal · doi:10.1016/s0006-3495(01)76173-5 · Cited by 442
Metadata
- Authors
- König, K., Becker, T. W., Fischer, P., Riemann, I., & Halbhuber, K.-J.
- Venue
- Optics Letters
- Publisher
- Optica Publishing Group
- Published
- 1999-01-15
- Volume
- 24
- Issue
- 2
- Pages
- 113
- ISSN
- 0146-9592 (ISSN-L)
- 1539-4794
- OpenAlex
- W2040815295
- Cited by
- 259
- References
- 0
- FWCI
- 10.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Pulse-length dependence of cellular response to intense near-infrared laser pulses in multiphoton microscopes. https://app.cochat.ai/papers/10.1364/ol.24.000113
- The paper
- König, K., Becker, T. W., Fischer, P., Riemann, I., & Halbhuber, K.-J. (1999). Pulse-length dependence of cellular response to intense near-infrared laser pulses in multiphoton microscopes. Optics Letters. https://doi.org/10.1364/ol.24.000113
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.