The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Pulse compression by use of deformable mirrors
Abstract
An electrostatically deformable, gold-coated, silicon nitride membrane mirror was used as a phase modulator to compress pulses from 92 to 15 fs. Both an iterative genetic algorithm and single-step dispersion compensation based on frequency-resolved optical gating calibration of the mirror were used to compress pulses to within 10% of the transform limit. Frequency-resolved optical gating was used to characterize the pulses and to test the range of the deformable-mirror-based compressor.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Optical pulse compression with diffraction gratings
Treacy, E. (1969) · IEEE Journal of Quantum Electronics · doi:10.1109/jqe.1969.1076303 · Cited by 1,363
Negative dispersion using pairs of prisms
Fork, R. L., Martinez, O. E., & Gordon, J. P. (1984) · Optics Letters · doi:10.1364/ol.9.000150 · Cited by 944
Feedback quantum control of molecular electronic population transfer
Bardeen, C. J., Yakovlev, V. V., Wilson, K. R., Carpenter, S. D., Weber, P. M., & Warren, W. S. (1997) · Chemical Physics Letters · doi:10.1016/s0009-2614(97)01081-6 · Cited by 529
Generation of 11-fs pulses from a self-mode-locked Ti:sapphire laser
Asaki, M. T., Huang, C.-P., Garvey, D., Zhou, J., Kapteyn, H. C., & Murnane, M. M. (1993) · Optics Letters · doi:10.1364/ol.18.000977 · Cited by 422
Self-citationAdaptive femtosecond pulse compression
Yelin, D., Meshulach, D., & Silberberg, Y. (1997) · Optics Letters · doi:10.1364/ol.22.001793 · Cited by 260
Temporal phase control of soft-x-ray harmonic emission
Chang, Z., Rundquist, A., Wang, H., Christov, I., Kapteyn, H. C., & Murnane, M. M. (1998) · Physical Review A · doi:10.1103/physreva.58.r30 · Cited by 181
Self-citationFlexible mirror micromachined in silicon
Vdovin, G., & Sarro, P. M. (1995) · Applied Optics · doi:10.1364/ao.34.002968 · Cited by 179
Self-citationDesign of high-power ultrashort pulse amplifiers by expansion and recompression
Martínez, O. E. (1987) · IEEE Journal of Quantum Electronics · doi:10.1109/jqe.1987.1073518 · Cited by 114
Wave-front correction of femtosecond terawatt lasers by deformable mirrors
Druon, F., Chériaux, G., Faure, J., et al. (1998) · Optics Letters · doi:10.1364/ol.23.001043 · Cited by 103
Adaptive ultrashort pulse compression and shaping
Meshulach, D., Yelin, D., & Silberberg, Y. R. (1997) · Optics Communications · doi:10.1016/s0030-4018(97)00090-4 · Cited by 59
Cited by
Shaped-pulse optimization of coherent emission of high-harmonic soft X-rays
Bartels, R., Backus, S., Zeek, E., Misoguti, L., Vdovin, G., Christov, I. P., Murnane, M. M., & Kapteyn, H. C. (2000) · Nature · doi:10.1038/35018029 · Cited by 713
Self-citationColloquium: Optimal control of high-harmonic generation
Winterfeldt, C., Spielmann, C., & Gerber, G. (2008) · Reviews of Modern Physics · doi:10.1103/revmodphys.80.117 · Cited by 384
Metadata
- Authors
- Zeek, E., Maginnis, K., Backus, S., Russek, U., Murnane, M., Mourou, G., Kapteyn, H., & Vdovin, G.
- Venue
- Optics Letters
- Publisher
- Optica Publishing Group
- Published
- 1999-04-01
- Volume
- 24
- Issue
- 7
- Pages
- 493
- ISSN
- 0146-9592 (ISSN-L)
- 1539-4794
- OpenAlex
- W1999342484
- Cited by
- 277
- References
- 11
- FWCI
- 12.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Pulse compression by use of deformable mirrors. https://app.cochat.ai/papers/10.1364/ol.24.000493
- The paper
- Zeek, E., Maginnis, K., Backus, S., Russek, U., Murnane, M., Mourou, G., Kapteyn, H., & Vdovin, G. (1999). Pulse compression by use of deformable mirrors. Optics Letters. https://doi.org/10.1364/ol.24.000493
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.