The DOI matches its Crossref record.
Membrane imaging by simultaneous second-harmonic generation and two-photon microscopy
Abstract
We demonstrate that simultaneous second-harmonic generation (SHG) and two-photon-excited fluorescence (TPEF) can be used to rapidly image biological membranes labeled with a styryl dye. The SHG power is made compatible with the TPEF power by use of near-resonance excitation, in accord with a model based on the theory of phased-array antennas, which shows that the SHG radiation is highly structured. Because of its sensitivity to local asymmetry, SHG microscopy promises to be a powerful tool for the study of membrane dynamics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Deep tissue two-photon microscopy
Helmchen, F., & Denk, W. (2005) · Nature Methods · doi:10.1038/nmeth818 · Cited by 4,153
Nonlinear magic: multiphoton microscopy in the biosciences
Zipfel, W. R., Williams, R. M., & Webb, W. W. (2003) · Nature Biotechnology · doi:10.1038/nbt899 · Cited by 3,893
Campagnola, P. J., & Loew, L. M. (2003) · Nature Biotechnology · doi:10.1038/nbt894 · Cited by 1,326
Principles of two-photon excitation microscopy and its applications to neuroscience
Svoboda, K., & Yasuda, R. (2006) · Neuron · doi:10.1016/j.neuron.2006.05.019 · Cited by 1,027
Campagnola, P. J., Millard, A. C., Terasaki, M., Hoppe, P. E., Malone, C. J., & Mohler, W. A. (2002) · Biophysical Journal · doi:10.1016/s0006-3495(02)75414-3 · Cited by 917
Metadata
- Authors
- Moreaux, L., Sandre, O., Blanchard-Desce, M., & Mertz, J.
- Venue
- Optics Letters
- Publisher
- Optica Publishing Group
- Published
- 2000-03-01
- Volume
- 25
- Issue
- 5
- Pages
- 320
- ISSN
- 0146-9592 (ISSN-L)
- 1539-4794
- OpenAlex
- W2044885070
- Cited by
- 209
- References
- 0
- FWCI
- 8.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Membrane imaging by simultaneous second-harmonic generation and two-photon microscopy. https://app.cochat.ai/papers/10.1364/ol.25.000320
- The paper
- Moreaux, L., Sandre, O., Blanchard-Desce, M., & Mertz, J. (2000). Membrane imaging by simultaneous second-harmonic generation and two-photon microscopy. Optics Letters. https://doi.org/10.1364/ol.25.000320
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.