Closed-loop aberration correction by use of a modal Zernike wave-front sensor
Abstract
We describe the practical implementation of a closed-loop adaptive-optics system incorporating a novel modal wave-front sensor. The sensor consists of a static binary-phase computer-generated holographic element, which generates a pattern of spots in a detector plane. Intensity differences between symmetric pairs of these spots give a direct measure of the Zernike mode amplitudes that are present in the input wave front. We use a ferroelectric liquid-crystal spatial light modulator in conjunction with a 4-f system and a spatial filter as a wave-front correction element. We present results showing a rapid increase in Strehl ratio and focal spot quality as the system corrects for deliberately introduced aberrations.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“This approach therefore generalizes to vector beams the mode sensing technique that has been used for years in multichannel correlators35 and in modal wavefront sensors36, and recently also for the orbital angular momentum density of light37.”
From Vector Beam Polarization State Spectrum Analyzer (2017) · cites this paper as [36]
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 4
Cited by
Sorted by citations
Vector Beam Polarization State Spectrum Analyzer
Moreno, I., Davis, J. A., Badham, K., Sánchez-López, M. M., Holland, J. E., & Cottrell, D. M. (2017) · Scientific Reports · doi:10.1038/s41598-017-02328-5 · Cited by 31
Metadata
- Authors
- Neil, M. A. A., Booth, M. J., & Wilson, T.
- Venue
- Optics Letters
- Publisher
- Optica Publishing Group
- Published
- 2000-08-01
- Volume
- 25
- Issue
- 15
- Pages
- 1083
- ISSN
- 0146-9592
- 1539-4794
- Cited by
- 93
- References
- 0
- Language
- en
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review