The DOI matches its Crossref record.
High-speed fiber–based polarization-sensitive optical coherence tomography of in vivo human skin
Open accessAbstract
A high-speed single-mode fiber-based polarization-sensitive optical coherence tomography (PS OCT) system was developed. With a polarization modulator, Stokes parameters of reflected flight for four input polarization states are measured as a function of depth. A phase modulator in the reference arm of a Michelson interferometer permits independent control of the axial scan rate and carrier frequency. In vivo PS OCT images of human skin are presented, showing subsurface structures that are not discernible in conventional OCT images. A phase retardation image in tissue is calculated based on the reflected Stokes parameters of the four input polarization states.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Biomechanical Properties of In Vivo Human Skin From Dynamic Optical Coherence Elastography
Liang, X., & Boppart, S. A. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2033464 · Cited by 470
Hitzenberger, C., Goetzinger, E., Sticker, M., Pircher, M., & Fercher, A. (2001) · Optics Express · doi:10.1364/oe.9.000780 · Cited by 391
Tang, P., Kirby, M. A., Le, N., Li, Y., Zeinstra, N., Lu, G. N., Murry, C. E., Zheng, Y., & Wang, R. K. (2021) · Light: Science & Applications · doi:10.1038/s41377-021-00679-3 · Cited by 83
Metadata
- Authors
- Saxer, C. E., de Boer, J. F., Park, B. H., Zhao, Y., Chen, Z., & Nelson, J. S.
- Venue
- Optics Letters
- Publisher
- Optica Publishing Group
- Published
- 2000-09-15
- Volume
- 25
- Issue
- 18
- Pages
- 1355
- ISSN
- 0146-9592 (ISSN-L)
- 1539-4794
- OpenAlex
- W2002775522
- Cited by
- 302
- References
- 0
- FWCI
- 13.14
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High-speed fiber–based polarization-sensitive optical coherence tomography of in vivo human skin. https://app.cochat.ai/papers/10.1364/ol.25.001355
- The paper
- Saxer, C. E., de Boer, J. F., Park, B. H., Zhao, Y., Chen, Z., & Nelson, J. S. (2000). High-speed fiber–based polarization-sensitive optical coherence tomography of in vivo human skin. Optics Letters. https://doi.org/10.1364/ol.25.001355
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.