Two-dimensional depth-resolved Mueller matrix of biological tissue measured with double-beam polarization-sensitive optical coherence tomography
Open accessAbstract
A double-beam polarization-sensitive system based on optical coherence tomography was built to measure the Mueller matrix of scattering biological tissue with high spatial resolution. The Jones matrix of a sample can be determined with a single scan and subsequently converted into an equivalent nondepolarizing Mueller matrix. As a result, the system can be used to measure the Mueller matrix of an unstable sample, such as soft tissue. The polarization parameters of a porcine tendon, including magnitude and orientation of birefringence and diattenuation, were extracted by decomposition of the measured Mueller matrix.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Optical coherence tomography - principles and applications
Fercher, A. F., Drexler, W., Hitzenberger, C. K., & Lasser, T. (2003) · Reports on Progress in Physics · doi:10.1088/0034-4885/66/2/204 · Cited by 1,866
Three dimensional optical angiography
Wang, R. K., Jacques, S. L., Ma, Z., Hurst, S., Hanson, S. R., & Gruber, A. (2007) · Optics Express · doi:10.1364/oe.15.004083 · Cited by 627
Polarization sensitive optical coherence tomography – a review [Invited]
de Boer, J. F., Hitzenberger, C. K., & Yasuno, Y. (2017) · Biomedical Optics Express · doi:10.1364/boe.8.001838 · Cited by 454
Review of polarization sensitive optical coherence tomography and Stokes vector determination
de Boer, J. F., & Milner, T. E. (2002) · Journal of Biomedical Optics · doi:10.1117/1.1483879 · Cited by 440
Gil, J. J. (2007) · The European Physical Journal Applied Physics · doi:10.1051/epjap:2007153 · Cited by 272
Metadata
- Authors
- Jiao, S., & Wang, L. V.
- Venue
- Optics Letters
- Publisher
- Optica Publishing Group
- Published
- 2002-01-15
- Volume
- 27
- Issue
- 2
- Pages
- 101
- ISSN
- 0146-9592 (ISSN-L)
- 1539-4794
- OpenAlex
- W2110533364
- Cited by
- 163
- References
- 0
- FWCI
- 14.95
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Two-dimensional depth-resolved Mueller matrix of biological tissue measured with double-beam polarization-sensitive optical coherence tomography. https://app.cochat.ai/papers/10.1364/ol.27.000101
- The paper
- Jiao, S., & Wang, L. V. (2002). Two-dimensional depth-resolved Mueller matrix of biological tissue measured with double-beam polarization-sensitive optical coherence tomography. Optics Letters. https://doi.org/10.1364/ol.27.000101
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.