The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
T-ray computed tomography
Open accessAbstract
We demonstrate a tomographic imaging modality that uses pulsed terahertz (THz) radiation to probe the optical properties of three-dimensional (3D) structures in the far-infrared. This THz-wave computed tomography (T-ray CT) system provides sectional images of objects in a manner analogous to conventional CT techniques such as x-ray CT. The transmitted amplitude and phase of broadband pulses of THz radiation are measured at multiple projection angles. The filtered backprojection algorithm is then used to reconstruct the target object, including both its 3D structure and its frequency-dependent far-infrared optical properties.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of Computerized Tomographic Imaging
Kak, A. C., & Slaney, M. (2001) · doi:10.1137/1.9780898719277 · Cited by 5,809
Image reconstruction from projections : the fundamentals of computerized tomography
Herman, G. T. (1980) · Academic Press eBooks · Cited by 1,993
Hu, B. B., & Nuss, M. C. (1995) · Optics Letters · doi:10.1364/ol.20.001716 · Cited by 1,648
Mittleman, D. M., Jacobsen, R. H., & Nuss, M. C. (1996) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/2944.571768 · Cited by 806
Recent advances in terahertz imaging
Mittleman, D. M., Gupta, M., Neelamani, R., Baraniuk, R. G., Rudd, J. V., & Koch, M. (1999) · Applied Physics B: Lasers and Optics · doi:10.1007/s003400050750 · Cited by 703
Mittleman, D. M., Hunsche, S., Boivin, L., & Nuss, M. C. (1997) · Optics Letters · doi:10.1364/ol.22.000904 · Cited by 519
Two-dimensional electro-optic imaging of THz beams
Wu, Q., Hewitt, T. D., & Zhang, X.-C. (1996) · Applied Physics Letters · doi:10.1063/1.116920 · Cited by 443
Self-citationNear-field terahertz imaging with a dynamic aperture
Chen, Q., Jiang, Z., Xu, G. X., & Zhang, X.-C. (2000) · Optics Letters · doi:10.1364/ol.25.001122 · Cited by 267
Self-citationElectro-optic measurement of THz field pulses with a chirped optical beam
Jiang, Z., & Zhang, X.-C. (1998) · Applied Physics Letters · doi:10.1063/1.121231 · Cited by 249
Self-citationTime-domain transillumination of biological tissues with terahertz pulses
Han, P. Y., Cho, G. C., & Zhang, X.-C. (2000) · Optics Letters · doi:10.1364/ol.25.000242 · Cited by 237
Self-citation
Cited by
Materials for terahertz science and technology
Ferguson, B., & Zhang, X.-C. (2002) · Nature Materials · doi:10.1038/nmat708 · Cited by 3,284
Self-citationImaging with terahertz radiation
Chan, W. L., Deibel, J., & Mittleman, D. M. (2007) · Reports on Progress in Physics · doi:10.1088/0034-4885/70/8/r02 · Cited by 965
Terahertz Imaging and Sensing Applications With Silicon-Based Technologies
Hillger, P., Grzyb, J., Jain, R., & Pfeiffer, U. R. (2019) · IEEE Transactions on Terahertz Science and Technology · doi:10.1109/tthz.2018.2884852 · Cited by 408
Terahertz time-domain spectroscopy
Koch, M., Mittleman, D. M., Ornik, J., & Castro-Camus, E. (2023) · Nature Reviews Methods Primers · doi:10.1038/s43586-023-00232-z · Cited by 410
Leemans, W. P., Geddes, C. G. R., Faure, J., Tóth, C., van Tilborg, J., Schroeder, C. B., Esarey, E., Fubiani, G., Auerbach, D., Marcelis, B., et al. (2003) · Physical Review Letters · doi:10.1103/physrevlett.91.074802 · Cited by 377
Metadata
- Authors
- Ferguson, B., Wang, S., Gray, D., Abbot, D., & Zhang, X.-C.
- Venue
- Optics Letters
- Publisher
- Optica Publishing Group
- Published
- 2002-08-01
- Volume
- 27
- Issue
- 15
- Pages
- 1312
- ISSN
- 0146-9592 (ISSN-L)
- 1539-4794
- OpenAlex
- W2069679176
- Cited by
- 321
- References
- 30
- FWCI
- 16.83
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: T-ray computed tomography. https://app.cochat.ai/papers/10.1364/ol.27.001312
- The paper
- Ferguson, B., Wang, S., Gray, D., Abbot, D., & Zhang, X.-C. (2002). T-ray computed tomography. Optics Letters. https://doi.org/10.1364/ol.27.001312
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.