The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Highly efficient single-photon detection at communication wavelengths by use of upconversion in reverse-proton-exchanged periodically poled LiNbO_3 waveguides
Abstract
Conventional single-photon detectors at communication wavelengths suffer from low quantum efficiencies and large dark counts. We present a single-photon detection system, operating at communication wavelengths, based on guided-wave frequency upconversion in a nonlinear crystal with an overall system detection efficiency (upconversion + detection) exceeding 46% at 1.56 microm. This system consists of a fiber-pigtailed reverse-proton-exchanged periodically poled LiNbO3 waveguide device in conjunction with a silicon-based single-photon counting module.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Efficient single-photon counting at 155 µm by means of frequency upconversion
Albota, M. A., & Wong, F. N. C. (2004) · Optics Letters · doi:10.1364/ol.29.001449 · Cited by 315
Parameswaran, K. R., Route, R. K., Kurz, J. R., Roussev, R. V., Fejer, M. M., & Fujimura, M. (2002) · Optics Letters · doi:10.1364/ol.27.000179 · Cited by 309
Self-citationDemonstration of a low-noise near-infrared photon counter with multiphoton discrimination
Miller, A. J., Nam, S. W., Martinis, J. M., & Sergienko, A. V. (2003) · Applied Physics Letters · doi:10.1063/1.1596723 · Cited by 285
High efficiency single photon detection via frequency up-conversion
Vandevender, A. P., & Kwiat, P. G. (2004) · Journal of Modern Optics · doi:10.1080/09500340408235283 · Cited by 214
Roussev, R. V., Langrock, C., Kurz, J. R., & Fejer, M. M. (2004) · Optics Letters · doi:10.1364/ol.29.001518 · Cited by 188
Self-citationRibordy, G., Gisin, N., Guinnard, O., Stuck, D., Wegmüller, M., & Zbinden, H. (2004) · Journal of Modern Optics · doi:10.1080/09500340408235280 · Cited by 107
14 MHz rate photon counting with room temperature InGaAs/InP avalanche photodiodes
Voss, P. L., Köprülü, K. G., Choi, S.-K., Dugan, S., & Kumar, P. (2004) · Journal of Modern Optics · doi:10.1080/09500340408235279 · Cited by 34
10.5 km Fiber-Optic Quantum Key Distribution at 1550 nm with a Key Rate of 45 kHz
Yoshizawa, A., Kaji, R., & Tsuchida, H. (2004) · Japanese Journal of Applied Physics · doi:10.1143/jjap.43.l735 · Cited by 30
Cited by
O'Brien, J. L., Furusawa, A., & Vučković, J. (2009) · Nature Photonics · doi:10.1038/nphoton.2009.229 · Cited by 2,388
Gisin, N., & Thew, R. (2007) · Nature Photonics · doi:10.1038/nphoton.2007.22 · Cited by 2,147
Single-photon detectors for optical quantum information applications
Hadfield, R. H. (2009) · Nature Photonics · doi:10.1038/nphoton.2009.230 · Cited by 1,726
Practical challenges in quantum key distribution
Diamanti, E., Lo, H.-K., Qi, B., & Yuan, Z. (2016) · npj Quantum Information · doi:10.1038/npjqi.2016.25 · Cited by 737
Self-citationStatus and Potential of Lithium Niobate on Insulator (LNOI) for Photonic Integrated Circuits
Boes, A., Corcoran, B., Chang, L., Bowers, J., & Mitchell, A. (2018) · Laser & Photonics Reviews · doi:10.1002/lpor.201700256 · Cited by 700
Metadata
- Authors
- Langrock, C., Diamanti, E., Roussev, R. V., Yamamoto, Y., Fejer, M. M., & Takesue, H.
- Venue
- Optics Letters
- Publisher
- Optica Publishing Group
- Published
- 2005-07-01
- Volume
- 30
- Issue
- 13
- Pages
- 1725
- ISSN
- 0146-9592 (ISSN-L)
- 1539-4794
- OpenAlex
- W2038795847
- Cited by
- 322
- References
- 8
- FWCI
- 12.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.