The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Local infrared microspectroscopy with subwavelength spatial resolution with an atomic force microscope tip used as a photothermal sensor
Abstract
We describe a new method of infrared microspectroscopy. It is intended for performing chemical mapping of various objects with subwavelength lateral resolution by using the infrared vibrational signature characterizing different molecular species. We use the photothermal expansion effect, detected by an atomic force microscope tip, probing the local transient deformation induced by an infrared pulsed laser tuned at a sample absorbing wavelength. We show that this new tool opens the way for measuring and identifying spectroscopic contrasts not accessible by far-field or near-field optical methods and with a subwavelength lateral resolution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Near-field probing of vibrational absorption for chemical microscopy
Knoll, B., & Keilmann, F. (1999) · Nature · doi:10.1038/20154 · Cited by 926
Hong, M., Jeung, A. G., Dokholyan, N. V., Smith, T. I., Schwettman, H. A., Huie, P., & Erramilli, S. (1998) · Nuclear Instruments and Methods in Physics Research Section B Beam Interactions with Materials and Atoms · doi:10.1016/s0168-583x(98)00311-5 · Cited by 47
IR microscopy with a transient photo-induced near-field probe (tipless near-field microscopy)
Palanker, D. V., Knippels, G. M. H., Smith, T. I., et al. (1998) · Optics Communications · doi:10.1016/s0030-4018(97)00702-5 · Cited by 31
Cited by
AFM-IR: Technology and Applications in Nanoscale Infrared Spectroscopy and Chemical Imaging
Dazzi, A., & Prater, C. B. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00448 · Cited by 1,082
Self-citationPhotovoltaic Switching Mechanism in Lateral Structure Hybrid Perovskite Solar Cells
Yuan, Y., Chae, J., Shao, Y., Wang, Q., Xiao, Z., Centrone, A., & Huang, J. (2015) · Advanced Energy Materials · doi:10.1002/aenm.201500615 · Cited by 713
High‐Gain and Low‐Driving‐Voltage Photodetectors Based on Organolead Triiodide Perovskites
Dong, R., Fang, Y., Chae, J., Dai, J., Xiao, Z., Dong, Q., Yuan, Y., Centrone, A., Zeng, X. C., & Huang, J. (2015) · Advanced Materials · doi:10.1002/adma.201405116 · Cited by 659
Dazzi, A., Prater, C. B., Hu, Q., Chase, D. B., Rabolt, J. F., & Marcott, C. (2012) · Applied Spectroscopy · doi:10.1366/12-06804 · Cited by 557
Self-citationTheory of infrared nanospectroscopy by photothermal induced resonance
Dazzi, A., Glotin, F., & Carminati, R. (2010) · Journal of Applied Physics · doi:10.1063/1.3429214 · Cited by 350
Self-citation
Metadata
- Authors
- Dazzi, A., Prazeres, R., Glotin, F., & Ortega, J. M.
- Venue
- Optics Letters
- Publisher
- Optica Publishing Group
- Published
- 2005-09-15
- Volume
- 30
- Issue
- 18
- Pages
- 2388
- ISSN
- 0146-9592 (ISSN-L)
- 1539-4794
- OpenAlex
- W1987320569
- Cited by
- 421
- References
- 3
- FWCI
- 2.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Local infrared microspectroscopy with subwavelength spatial resolution with an atomic force microscope tip used as a photothermal sensor. https://app.cochat.ai/papers/10.1364/ol.30.002388
- The paper
- Dazzi, A., Prazeres, R., Glotin, F., & Ortega, J. M. (2005). Local infrared microspectroscopy with subwavelength spatial resolution with an atomic force microscope tip used as a photothermal sensor. Optics Letters. https://doi.org/10.1364/ol.30.002388
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.