The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Broadly tunable dual-wavelength light source for coherent anti-Stokes Raman scattering microscopy
Abstract
The signal and idler beams from a picosecond, synchronously pumped optical parametric oscillator (OPO) provide the two colors necessary for coherent anti-Stokes Raman scattering (CARS) microscopy. The OPO provides a continuously tunable frequency difference between the two beams over a broad range of Raman shifts (100-3700 cm(-1)) by varying the temperature of a single nonlinear crystal. The near-infrared output (900-1300 nm) allows for deep penetration into thick samples and reduced nonlinear photodamage. Applications of this light source to in vivo cell and ex vivo tissue imaging are demonstrated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chemical imaging of tissue in vivo with video-rate coherent anti-Stokes Raman scattering microscopy
Evans, C. L., Potma, E. O., Puoris'haag, M., Côté, D., Lin, C. P., & Xie, X. S. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0508282102 · Cited by 957
Self-citationHighly Nonlinear Photodamage in Two-Photon Fluorescence Microscopy
Hopt, A., & Neher, E. (2001) · Biophysical Journal · doi:10.1016/s0006-3495(01)76173-5 · Cited by 442
Cited by
Coherent Anti-Stokes Raman Scattering Microscopy: Chemical Imaging for Biology and Medicine
Evans, C. L., & Xie, X. S. (2008) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.1.031207.112754 · Cited by 1,150
Stimulated Raman scattering microscopy with a robust fibre laser source
Freudiger, C. W., Yang, W., Holtom, G. R., Peyghambarian, N., Xie, X. S., & Kieu, K. Q. (2014) · Nature Photonics · doi:10.1038/nphoton.2013.360 · Cited by 345
Coherent anti‐Stokes Raman Scattering Microscopy
Müller, M., & Zumbusch, A. (2007) · ChemPhysChem · doi:10.1002/cphc.200700202 · Cited by 277
Metadata
- Authors
- Ganikhanov, F., Carrasco, S., Sunney Xie, X., Katz, M., Seitz, W., & Kopf, D.
- Venue
- Optics Letters
- Publisher
- Optica Publishing Group
- Published
- 2006-05-01
- Volume
- 31
- Issue
- 9
- Pages
- 1292
- ISSN
- 0146-9592 (ISSN-L)
- 1539-4794
- OpenAlex
- W2153351568
- Cited by
- 240
- References
- 2
- FWCI
- 7.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Broadly tunable dual-wavelength light source for coherent anti-Stokes Raman scattering microscopy. https://app.cochat.ai/papers/10.1364/ol.31.001292
- The paper
- Ganikhanov, F., Carrasco, S., Sunney Xie, X., Katz, M., Seitz, W., & Kopf, D. (2006). Broadly tunable dual-wavelength light source for coherent anti-Stokes Raman scattering microscopy. Optics Letters. https://doi.org/10.1364/ol.31.001292
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.