The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
In vivo measurement of retinal physiology with high-speed ultrahigh-resolution optical coherence tomography
Abstract
Noninvasive in vivo functional optical imaging of the intact retina is demonstrated by using high-speed, ultrahigh-resolution optical coherence tomography (OCT). Imaging was performed with 2.8 microm resolution at a rate of 24,000 axial scans per second. A white-light stimulus was applied to the dark-adapted rat retina, and the average reflectivities from different intraretinal layers were monitored as a function of time. A 10%-15% increase in the average amplitude reflectance of the photoreceptor outer segments was observed in response to the stimulus. The spatial distribution of the change in the OCT signal is consistent with an increase in backscatter from the photoreceptor outer segments. To our knowledge, this is the first in vivo demonstration of OCT functional imaging in the intact retina.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Light-evoked changes in the interphotoreceptor matrix
Uehara, F., Matthes, M. T., Yasumura, D., & LaVail, M. M. (1990) · Science · doi:10.1126/science.2194288 · Cited by 89
Cited by
State-of-the-art retinal optical coherence tomography
DREXLER, W., & FUJIMOTO, J. (2008) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2007.07.005 · Cited by 906
Self-citationKur, J., Newman, E. A., & Chan-Ling, T. (2012) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2012.04.004 · Cited by 678
Potsaid, B., Gorczynska, I., Srinivasan, V. J., Chen, Y., Jiang, J., Cable, A., & Fujimoto, J. G. (2008) · Optics Express · doi:10.1364/oe.16.015149 · Cited by 372
Self-citationMegahertz OCT for ultrawide-field retinal imaging with a 1050nm Fourier domain mode-locked laser
Klein, T., Wieser, W., Eigenwillig, C. M., Biedermann, B. R., & Huber, R. (2011) · Optics Express · doi:10.1364/oe.19.003044 · Cited by 318
Advances in Light Microscopy for Neuroscience
Wilt, B. A., Burns, L. D., Wei Ho, E. T., Ghosh, K. K., Mukamel, E. A., & Schnitzer, M. J. (2009) · Annual Review of Neuroscience · doi:10.1146/annurev.neuro.051508.135540 · Cited by 278
Metadata
- Authors
- Srinivasan, V. J., Wojtkowski, M., Fujimoto, J. G., & Duker, J. S.
- Venue
- Optics Letters
- Publisher
- Optica Publishing Group
- Published
- 2006-07-10
- Volume
- 31
- Issue
- 15
- Pages
- 2308
- ISSN
- 0146-9592 (ISSN-L)
- 1539-4794
- OpenAlex
- W2047049417
- Cited by
- 164
- References
- 1
- FWCI
- 13.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: In vivo measurement of retinal physiology with high-speed ultrahigh-resolution optical coherence tomography. https://app.cochat.ai/papers/10.1364/ol.31.002308
- The paper
- Srinivasan, V. J., Wojtkowski, M., Fujimoto, J. G., & Duker, J. S. (2006). In vivo measurement of retinal physiology with high-speed ultrahigh-resolution optical coherence tomography. Optics Letters. https://doi.org/10.1364/ol.31.002308
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.