Spiral-path high-sensitivity silicon photonic wire molecular sensor with temperature-independent response
Abstract
We demonstrate a new silicon photonic wire waveguide evanescent field (PWEF) sensor that exploits the strong evanescent field of the transverse magnetic mode of this high-index-contrast, submicrometer-dimension waveguide. High sensitivity is achieved by using a 2 mm long double-spiral waveguide structure that fits within a compact circular area of 150 microm diameter, facilitating compatibility with commercial spotting apparatus and the fabrication of densely spaced sensor arrays. By incorporating the PWEF sensor element into a balanced waveguide Mach-Zehnder interferometer circuit, a minimum detectable mass of approximately 10 fg of streptavidin protein is demonstrated with near temperature-independent response.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Integrated optical devices for lab‐on‐a‐chip biosensing applications
Estevez, M. C., Alvarez, M., & Lechuga, L. M. (2012) · Laser & Photonics Reviews · doi:10.1002/lpor.201100025 · Cited by 617
Silicon Photonic Biosensors Using Label-Free Detection
Luan, E., Shoman, H., Ratner, D. M., Cheung, K. C., & Chrostowski, L. (2018) · Sensors · doi:10.3390/s18103519 · Cited by 379
High-Q Optical Sensors for Chemical and Biological Analysis
Luchansky, M. S., & Bailey, R. C. (2012) · Analytical Chemistry · doi:10.1021/ac2029024 · Cited by 288
Highly sensitive Mach–Zehnder interferometer biosensor based on silicon nitride slot waveguide
Liu, Q., Tu, X., Kim, K. W., Kee, J. S., Shin, Y., Han, K., Yoon, Y.-J., Lo, G.-Q., & Park, M. K. (2013) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2013.07.053 · Cited by 253
Chakraborty, A., & Sarkar, A. (2017) · Journal of Computational Electronics · doi:10.1007/s10825-017-0999-2 · Cited by 94
Sub-20 nm GaAs junctionless FinFET for biosensing application
Chhabra, A., Kumar, A., & Chaujar, R. (2019) · Vacuum · doi:10.1016/j.vacuum.2018.12.007 · Cited by 44
Metadata
- Authors
- Densmore, A., Xu, D.-X., Janz, S., Waldron, P., Mischki, T., Lopinski, G., Delâge, A., Lapointe, J., Cheben, P., Lamontagne, B., & Schmid, J. H.
- Venue
- Optics Letters
- Publisher
- Optica Publishing Group
- Published
- 2008-03-14
- Volume
- 33
- Issue
- 6
- Pages
- 596
- ISSN
- 0146-9592 (ISSN-L)
- 1539-4794
- OpenAlex
- W2036269274
- Cited by
- 170
- References
- 0
- FWCI
- 14.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.