Development and preliminary results of an endoscopic Raman probe for potential in vivo diagnosis of lung cancers
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
A near-infrared Raman system was developed to collect real-time in vivo human lung spectra. The excitation light and the emission were guided to and from the tissue surface by a reusable fiber catheter passed down the instrument channel of a bronchoscope. Two-stage filtering was used to reduce laser noise, fluorescence, and Raman emissions from the fibers. A second fiber bundle guided the emission to a spectrometer where the fibers, in a round packing geometry, were spread out to form a parabolic arc that improved the signal-to-noise ratio 20-fold, facilitating real-time spectral measurements. Preliminary clinical tests show that clear and reliable Raman spectra can be obtained.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Raman Spectroscopy of Biological Tissues
Movasaghi, Z., Rehman, S., & Rehman, I. U. (2007) · Applied Spectroscopy Reviews · doi:10.1080/05704920701551530 · Cited by 2,518
Cited by
Kircher, M. F., de la Zerda, A., Jokerst, J. V., Zavaleta, C. L., Kempen, P. J., Mittra, E., Pitter, K., Huang, R., Campos, C., Habte, F., et al. (2012) · Nature Medicine · doi:10.1038/nm.2721 · Cited by 1,064
Zavaleta, C. L., Smith, B. R., Walton, I., Doering, W., Davis, G., Shojaei, B., Natan, M. J., & Gambhir, S. S. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0813327106 · Cited by 714
Vibrational spectroscopy: a clinical tool for cancer diagnostics
Kendall, C., Isabelle, M., Bazant-Hegemark, F., Hutchings, J., Orr, L., Babrah, J., Baker, R., & Stone, N. (2009) · The Analyst · doi:10.1039/b822130h · Cited by 293
Advantages and limitations of Raman spectroscopy for molecular diagnostics: an update
Eberhardt, K., Stiebing, C., Matthäus, C., Schmitt, M., & Popp, J. (2015) · Expert Review of Molecular Diagnostics · doi:10.1586/14737159.2015.1036744 · Cited by 282
In-vivo Raman spectroscopy: from basics to applications
Cordero, E. (2018) · Journal of Biomedical Optics · doi:10.1117/1.jbo.23.7.071210 · Cited by 195
“Another clinical setup was introduced byMotz et al.,49 which uses a sapphire ball lens with a 2-mm diameter and a coupled fiber probe with 15 collection fibers.50 Here, filters deposited on a special glass substrate were used, instead of directly coating the fiber ends.43 The probe was applied for margin assessment du…”
BackgroundMagneto‐Plasmonic Au‐Fe Alloy Nanoparticles Designed for Multimodal SERS‐MRI‐CT Imaging
Amendola, V., Scaramuzza, S., Litti, L., Meneghetti, M., Zuccolotto, G., Rosato, A., Nicolato, E., Marzola, P., Fracasso, G., Anselmi, C., et al. (2014) · Small · doi:10.1002/smll.201303372 · Cited by 189
Raman spectroscopy for cancer detection and cancer surgery guidance: translation to the clinics
Santos, I. P., Barroso, E. M., Bakker Schut, T. C., Caspers, P. J., van Lanschot, C. G. F., Choi, D.-H., van der Kamp, M. F., Smits, R. W. H., van Doorn, R., Verdijk, R. M., et al. (2017) · The Analyst · doi:10.1039/c7an00957g · Cited by 169
Full range characterization of the Raman spectra of organs in a murine model
Huang, N., Short, M., Zhao, J., Wang, H., Lui, H., Korbelik, M., & Zeng, H. (2011) · Optics Express · doi:10.1364/oe.19.022892 · Cited by 131
Self-citationLi, X., Zhou, R., Xu, Y., Wei, X., & He, Y. (2017) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2016.1226183 · Cited by 13
“However, formula (5) is a non-deterministic polynomial hard problem which cannot be solved easily.”
Background
Metadata
- Authors
- Short, M. A., Lam, S., McWilliams, A., Zhao, J., Lui, H., & Zeng, H.
- Venue
- Optics Letters
- Publisher
- Optica Publishing Group
- Published
- 2008-03-28
- Volume
- 33
- Issue
- 7
- Pages
- 711
- ISSN
- 0146-9592 (ISSN-L)
- 1539-4794
- OpenAlex
- W2088159530
- Cited by
- 148
- References
- 1
- FWCI
- 6.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.