CoChat

Ultralow-frequency-noise stabilization of a laser by locking to an optical fiber-delay line

Open access
Kéfélian, Fabien, Jiang, Haifeng, Lemonde, Pierre, Santarelli, Giorgio · 2009 · Optics Letters
Cited by 181

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

We report the frequency stabilization of an erbium-doped fiber distributed-feedback laser using an all-fiber-based Michelson interferometer of large arm imbalance. The interferometer uses a 1 km SMF-28 optical fiber spool and an acousto-optic modulator allowing heterodyne detection. The frequency-noise power spectral density is reduced by more than 40 dB for Fourier frequencies ranging from 1 Hz to 10 kHz, corresponding to a level well below 1 Hz2/Hz over the entire range; it reaches 10(-2) Hz2/Hz at 1 kHz. Between 40 Hz and 30 kHz, the frequency noise is shown to be comparable to the one obtained by Pound-Drever-Hall locking to a high-finesse Fabry-Perot cavity. Locking to a fiber delay line could consequently represent a reliable, simple, and compact alternative to cavity stabilization for short-term linewidth reduction.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1364/ol.34.000914

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

  • Laser phase and frequency stabilization using an optical resonator

    Drever, R. W. P., Hall, J. L., Kowalski, F. V., Hough, J., Ford, G. M., Munley, A. J., & Ward, H. (1983) · Applied Physics B Photophysics and Laser Chemistry · doi:10.1007/bf00702605 · Cited by 3,811 · cited 1×

    “is method generally does not provide fast frequency noise reduction. The linewidth of lasers is then usually reduced by 1 locking to an ultra-stable optical cavity, using the Pound-Drever-Hall method [1] [2] [3]. It led to fractional frequency instability lower than 10−15 for 1 s averaging times and subhertz linewidth…”
  • Visible Lasers with Subhertz Linewidths

    Young, B. C., Cruz, F. C., Itano, W. M., & Bergquist, J. C. (1999) · Physical Review Letters · doi:10.1103/physrevlett.82.3799 · Cited by 605 · cited 1×

    “1 locking to an ultra-stable optical cavity, using the Pound-Drever-Hall method [1] [2] [3]. It led to fractional frequency instability lower than 10−15 for 1 s averaging times and subhertz linewidth [4]. But this scheme requires fine alignment of free space optical components, tight polarization adjustment and spatial…”
  • Thermal-Noise Limit in the Frequency Stabilization of Lasers with Rigid Cavities

    Numata, K., Kemery, A., & Camp, J. (2004) · Physical Review Letters · doi:10.1103/physrevlett.93.250602 · Cited by 554 · cited 1×

    “Their stability is ultimately limited by fundamental thermodynamics fluctuations in mirrors substrates and coatings [7].”
  • Compact, thermal-noise-limited optical cavity for diode laser stabilization at 1×10^−15

    Ludlow, A. D., Huang, X., Notcutt, M., Zanon-Willette, T., Foreman, S. M., Boyd, M. M., Blatt, S., & Ye, J. (2007) · Optics Letters · doi:10.1364/ol.32.000641 · Cited by 372 · cited 1×

    “ethod generally does not provide fast frequency noise reduction. The linewidth of lasers is then usually reduced by 1 locking to an ultra-stable optical cavity, using the Pound-Drever-Hall method [1] [2] [3]. It led to fractional frequency instability lower than 10−15 for 1 s averaging times and subhertz linewidth [4]…”
    Method
  • Long-distance frequency transfer over an urban fiber link using optical phase stabilization

    Jiang, H., Kéfélian, F., Crane, S., Lopez, O., Lours, M., Millo, J., Holleville, D., Lemonde, P., Chardonnet, C., Amy-Klein, A., et al. (2008) · Journal of the Optical Society of America B · doi:10.1364/josab.25.002029 · Cited by 166 · cited 1×

    “The frequency noise power spectral density (PSD) of the fiber stabilized laser is measured by comparison with a high-finesse Fabry-Perot cavity stabilized laser described in [12].”
    Self-citation
  • Thermal-noise-limited optical cavity

    Webster, S. A., Oxborrow, M., Pugla, S., Millo, J., & Gill, P. R. (2008) · Physical Review A · doi:10.1103/physreva.77.033847 · Cited by 140 · cited 1×

    “d generally does not provide fast frequency noise reduction. The linewidth of lasers is then usually reduced by 1 locking to an ultra-stable optical cavity, using the Pound-Drever-Hall method [1] [2] [3]. It led to fractional frequency instability lower than 10−15 for 1 s averaging times and subhertz linewidth [4]. Bu…”
  • High-bandwidth laser frequency stabilization to a fiber-optic delay line

    Sheard, B., Gray, M. B., & McClelland, D. E. (2006) · Applied Optics · doi:10.1364/ao.45.008491 · Cited by 55 · cited 2×

    “This can be partially overcome by designing sophisticated loop filter controllers [9].”

Show all 7 references

Cited by

Metadata

Authors
Kéfélian, F., Jiang, H., Lemonde, P., & Santarelli, G.
Venue
Optics Letters
Published
2009-03-18
Volume
34
Issue
7
Pages
914
ISSN
  • 0146-9592 (ISSN-L)
  • 1539-4794
OpenAlex
W3082258109
Cited by
181
References
7
FWCI
4.83
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.