The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Femtosecond fiber CPA system emitting 830 W average output power
Abstract
In this Letter we report on the generation of 830 W compressed average power from a femtosecond fiber chirped pulse amplification (CPA) system. In the high-power operation we achieved a compressor throughput of about 90% by using high-efficiency dielectric gratings. The output pulse duration of 640 fs at 78 MHz repetition rate results in a peak power of 12 MW. Additionally, we discuss further a scaling potential toward and beyond the kilowatt level by overcoming the current scaling limitations imposed by the transversal spatial hole burning.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Compression of amplified chirped optical pulses
Strickland, D., & Mourou, G. (1985) · Optics Communications · doi:10.1016/0030-4018(85)90120-8 · Cited by 3,937
Compression of amplified chirped optical pulses
Strickland, D., & Mourou, G. (1985) · Optics Communications · doi:10.1016/0030-4018(85)90151-8 · Cited by 1,237
Millijoule pulse energy high repetition rate femtosecond fiber chirped-pulse amplification system
Roser, F., Eidam, T., Rothhardt, J., Schmidt, O., Schimpf, D. N., Limpert, J., & Tünnermann, A. (2007) · Optics Letters · doi:10.1364/ol.32.003495 · Cited by 291
Self-citationGong, M., Yuan, Y., Li, C., Yan, P., Zhang, H., & Liao, S. (2007) · Optics Express · doi:10.1364/oe.15.003236 · Cited by 177
High Repetition Rate Gigawatt Peak Power Fiber Laser Systems: Challenges, Design, and Experiment
Limpert, J., Roser, F., Schimpf, D. N., et al. (2009) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/jstqe.2008.2010244 · Cited by 92
Self-citationApplication of high harmonic radiation in surface science
Haarlammert, T., & Zacharias, H. (2009) · Current Opinion in Solid State and Materials Science · doi:10.1016/j.cossms.2008.12.003 · Cited by 50
A 325-W-Average-Power Fiber CPA System Delivering Sub-400 fs Pulses
Eidam, T., Hädrich, S., Roser, F., et al. (2009) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/jstqe.2008.2010266 · Cited by 28
Self-citation
Cited by
(2006) · Elsevier eBooks · doi:10.1016/b978-0-12-369516-1.x5000-6 · Cited by 2,074
High Power Fiber Lasers: A Review
Zervas, M. N., & Codemard, C. A. (2014) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/jstqe.2014.2321279 · Cited by 1,194
Attosecond Electron Dynamics in Molecules
Nisoli, M., Decleva, P., Calegari, F., Palacios, A., & Martín, F. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00453 · Cited by 558
Direct frequency comb spectroscopy in the extreme ultraviolet
Cingöz, A., Yost, D. C., Allison, T. K., Ruehl, A., Fermann, M. E., Hartl, I., & Ye, J. (2012) · Nature · doi:10.1038/nature10711 · Cited by 477
Compact diode-pumped 11 kW Yb:YAG Innoslab femtosecond amplifier
Russbueldt, P., Mans, T., Weitenberg, J., Hoffmann, H. D., & Poprawe, R. (2010) · Optics Letters · doi:10.1364/ol.35.004169 · Cited by 462
Metadata
- Authors
- Eidam, T., Hanf, S., Seise, E., Andersen, T. V., Gabler, T., Wirth, C., Schreiber, T., Limpert, J., & Tünnermann, A.
- Venue
- Optics Letters
- Publisher
- Optica Publishing Group
- Published
- 2010-01-05
- Volume
- 35
- Issue
- 2
- Pages
- 94
- ISSN
- 0146-9592 (ISSN-L)
- 1539-4794
- OpenAlex
- W2054058426
- Cited by
- 616
- References
- 7
- FWCI
- 46.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.