The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Compact diode-pumped 11 kW Yb:YAG Innoslab femtosecond amplifier
Abstract
We demonstrate a compact diode-pumped Yb:KGW femtosecond oscillator-Yb:YAG Innoslab amplifier master oscillator power amplifier (MOPA) with nearly transform-limited 636 fs pulses at 620 W average output power, 20 MHz repetition rate, and beam quality of M(x)(2) = 1.43 and M(y)(2) = 1.35. By cascading two amplifiers, we attain an average output power of 1.1 kW, a peak power of 80 MW, and a 615 fs pulse width in a single linearly polarized beam. The power-scalable MOPA is operated at room temperature, and no chirped-pulse amplification technique is used.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Laser ablation and micromachining with ultrashort laser pulses
Liu, X., Du, D., & Mourou, G. (1997) · IEEE Journal of Quantum Electronics · doi:10.1109/3.631270 · Cited by 972
Femtosecond fiber CPA system emitting 830 W average output power
Eidam, T., Hanf, S., Seise, E., Andersen, T. V., Gabler, T., Wirth, C., Schreiber, T., Limpert, J., & Tünnermann, A. (2010) · Optics Letters · doi:10.1364/ol.35.000094 · Cited by 616
Femtosecond laser oscillators for high-field science
Südmeyer, T., Marchese, S. V., Hashimoto, S., Baer, C. R. E., Gingras, G., Witzel, B., & Keller, U. (2008) · Nature Photonics · doi:10.1038/nphoton.2008.194 · Cited by 200
Metzger, T., Schwarz, A., Teisset, C. Y., et al. (2009) · Optics Letters · doi:10.1364/ol.34.002123 · Cited by 175
90 mJ parametric chirped pulse amplification of 10 fs pulses
Tavella, F., Marcinkevičius, A., & Krausz, F. (2006) · Optics Express · doi:10.1364/oe.14.012822 · Cited by 129
Femtosecond vs. Picosecond Laser Material Processing
Tuennermann, A., Nolte, S., & Limpert, J. (2010) · Laser Technik Journal · doi:10.1002/latj.201090006 · Cited by 48
Cited by
Surface Structuring with Ultra-short Laser Pulses: Basics, Limitations and Needs for High Throughput
Neuenschwander, B., Jaeggi, B., Schmid, M., & Hennig, G. (2014) · Physics Procedia · doi:10.1016/j.phpro.2014.08.017 · Cited by 194
Optimization of the volume ablation rate for metals at different laser pulse-durations from ps to fs
Neuenschwander, B., Jaeggi, B., Schmid, M., Rouffiange, V., & Martin, P.-E. (2012) · SPIE Proceedings · doi:10.1117/12.908583 · Cited by 119
Bechtold, P., Hohenstein, R., & Schmidt, M. (2013) · Optics Letters · doi:10.1364/ol.38.002934 · Cited by 35
Schille, J., Schneider, L., Streek, A., Kloetzer, S., & Loeschner, U. (2016) · SPIE Proceedings · doi:10.1117/12.2220112 · Cited by 20
Metadata
- Authors
- Russbueldt, P., Mans, T., Weitenberg, J., Hoffmann, H. D., & Poprawe, R.
- Venue
- Optics Letters
- Publisher
- Optica Publishing Group
- Published
- 2010-12-13
- Volume
- 35
- Issue
- 24
- Pages
- 4169
- ISSN
- 0146-9592 (ISSN-L)
- 1539-4794
- OpenAlex
- W1993731696
- Cited by
- 462
- References
- 6
- FWCI
- 19.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Compact diode-pumped 11 kW Yb:YAG Innoslab femtosecond amplifier. https://app.cochat.ai/papers/10.1364/ol.35.004169
- The paper
- Russbueldt, P., Mans, T., Weitenberg, J., Hoffmann, H. D., & Poprawe, R. (2010). Compact diode-pumped 11 kW Yb:YAG Innoslab femtosecond amplifier. Optics Letters. https://doi.org/10.1364/ol.35.004169
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.