A spectrally constrained dual-band normalization technique for protoporphyrin IX quantification in fluorescence-guided surgery
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
We report a dual-band normalization technique for in vivo quantification of the metabolic biomarker, protoporphyrin IX (PpIX), during brain tumor resection procedures. The accuracy of the approach was optimized in tissue simulating phantoms with varying absorption and scattering properties, validated with fluorimetric assessments on ex vivo brain tissue, and tested on human data acquired in vivo during fluorescence-guided surgery of brain tumors. The results demonstrate that the dual-band normalization technique allows PpIX concentrations to be accurately quantified by correction with reflectance data recorded and integrated within only two narrow wavelength intervals. The simplicity of the method lends itself to the enticing prospect that the method could be applicable to wide-field applications in quantitative fluorescence imaging and dosimetry in photodynamic therapy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Stummer, W., Pichlmeier, U., Meinel, T., Wiestler, O. D., Zanella, F., & Reulen, H.-J. (2006) · The Lancet Oncology · doi:10.1016/s1470-2045(06)70665-9 · Cited by 3,423
Cited by
Valdés, P. A., Jacobs, V., Harris, B. T., Wilson, B. C., Leblond, F., Paulsen, K. D., & Roberts, D. W. (2015) · Journal of Neurosurgery · doi:10.3171/2014.12.jns14391 · Cited by 170
“…operating microscope, these probe measurements are semiquantitative 44 and do not account for the variable attenuation caused by tissue optical properties on the detected fluorescence, 3,16,25,28,44,49,50 and therefore, do not calculate the absolute fluorescent biomarker concentrations.”
Self-citationKaneko, S., Suero Molina, E., Ewelt, C., Warneke, N., & Stummer, W. (2019) · Neurosurgery · doi:10.1093/neuros/nyz129 · Cited by 56
Bravo, J. J., Olson, J. D., Davis, S. C., Roberts, D. W., Paulsen, K. D., & Kanick, S. C. (2017) · Scientific Reports · doi:10.1038/s41598-017-09727-8 · Cited by 53
Self-citationBlack, D., Kaneko, S., Walke, A., König, S., Stummer, W., & Suero Molina, E. (2021) · Scientific Reports · doi:10.1038/s41598-021-99228-6 · Cited by 46
Suero Molina, E., Black, D., Kaneko, S., Müther, M., & Stummer, W. (2022) · Journal of Neurosurgery · doi:10.3171/2021.12.jns211724 · Cited by 28
Metadata
- Authors
- Valdés, P. A., Leblond, F., Kim, A., Wilson, B. C., Paulsen, K. D., & Roberts, D. W.
- Venue
- Optics Letters
- Publisher
- Optica Publishing Group
- Published
- 2012-05-17
- Volume
- 37
- Issue
- 11
- Pages
- 1817
- ISSN
- 0146-9592 (ISSN-L)
- 1539-4794
- OpenAlex
- W2078893182
- Cited by
- 60
- References
- 1
- FWCI
- 3.12
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.