Sub-two-cycle, carrier-envelope phase-stable, intense optical pulses at 16 μm from a BiB_3O_6optical parametric chirped-pulse amplifier
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
We report on the generation of 9.0 fs, 550 μJ, carrier-envelope phase (CEP)-stabilized optical pulses around 1.6 μm at 1 kHz. Few-cycle IR pulses are obtained from a BiB(3)O(6) optical parametric chirped-pulse amplifier. The amplification of nearly octave-spanning ultrabroad pulses without spectral broadening results in good stability in output energy (0.85% rms) and CEP (160 mrad rms). We observed high harmonics in the water window from a neon cell that corresponds to a laser intensity of 4.1×10(14) W/cm(2).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bright Coherent Ultrahigh Harmonics in the keV X-ray Regime from Mid-Infrared Femtosecond Lasers
Popmintchev, T., Chen, M.-C., Popmintchev, D., Arpin, P., Brown, S., Ališauskas, S., Andriukaitis, G., Balčiunas, T., Mücke, O. D., Pugzlys, A., et al. (2012) · Science · doi:10.1126/science.1218497 · Cited by 1,830
Compression of 1.8 μm laser pulses to sub two optical cycles with bulk material
Schmidt, B. E., Béjot, P., Giguère, M., Shiner, A. D., Trallero-Herrero, C., Bisson, É., Kasparian, J., Wolf, J.-P., Villeneuve, D. M., Kieffer, J.-C., et al. (2010) · Applied Physics Letters · doi:10.1063/1.3359458 · Cited by 150
Cited by
Attosecond science based on high harmonic generation from gases and solids
Li, J., Lu, J., Chew, A., Han, S., Li, J., Wu, Y., Wang, H., Ghimire, S., & Chang, Z. (2020) · Nature Communications · doi:10.1038/s41467-020-16480-6 · Cited by 334
Ishii, N., Kaneshima, K., Kitano, K., Kanai, T., Watanabe, S., & Itatani, J. (2014) · Nature Communications · doi:10.1038/ncomms4331 · Cited by 228
Self-citationCoherent pulse synthesis: towards sub-cycle optical waveforms
Manzoni, C., Mücke, O. D., Cirmi, G., Fang, S., Moses, J., Huang, S.-W., Hong, K.-H., Cerullo, G., & Kärtner, F. X. (2015) · Laser & Photonics Reviews · doi:10.1002/lpor.201400181 · Cited by 225
Frequency domain optical parametric amplification
Schmidt, B. E., Thiré, N., Boivin, M., Laramée, A., Poitras, F., Lebrun, G., Ozaki, T., Ibrahim, H., & Légaré, F. (2014) · Nature Communications · doi:10.1038/ncomms4643 · Cited by 179
Development of high harmonic generation spectroscopy of organic molecules and biomolecules
Marangos, J. P. (2016) · Journal of Physics B: Atomic, Molecular and Optical Physics · doi:10.1088/0953-4075/49/13/132001 · Cited by 111
Metadata
- Authors
- Ishii, N., Kaneshima, K., Kitano, K., Kanai, T., Watanabe, S., & Itatani, J.
- Venue
- Optics Letters
- Publisher
- Optica Publishing Group
- Published
- 2012-10-02
- Volume
- 37
- Issue
- 20
- Pages
- 4182
- ISSN
- 0146-9592 (ISSN-L)
- 1539-4794
- OpenAlex
- W2021211284
- Cited by
- 102
- References
- 2
- FWCI
- 4.98
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Sub-two-cycle, carrier-envelope phase-stable, intense optical pulses at 16 μm from a BiB_3O_6optical parametric chirped-pulse amplifier. https://app.cochat.ai/papers/10.1364/ol.37.004182
- The paper
- Ishii, N., Kaneshima, K., Kitano, K., Kanai, T., Watanabe, S., & Itatani, J. (2012). Sub-two-cycle, carrier-envelope phase-stable, intense optical pulses at 16 μm from a BiB_3O_6optical parametric chirped-pulse amplifier. Optics Letters. https://doi.org/10.1364/ol.37.004182
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.