Cited by 75Laser-Matter Interactions and ApplicationsPhotonic Crystal and Fiber OpticsAdvanced Fiber Laser Technologies

Parametric amplification of 100 fs mid-infrared pulses in ZnGeP_2 driven by a Ho:YAG chirped-pulse amplifier

Kanai, Tsuneto, Malevich, Pavel, Kangaparambil, Sarayoo Sasidharan, Ishida, Kakuta, Mizui, Makoto, Yamanouchi, Kaoru, Hoogland, Heinar, Holzwarth, Ronald +2 more·2017·Optics Letters

Abstract

We report on the parametric generation of 100 fs sub-6-cycle 40 μJ pulses with the center wavelength at 5.2 μm using a 1 ps 2.1 μm pump laser and a dispersion management scheme based on bulk material. Our optically synchronized amplifier chain consists of a Ho:YAG chirped-pulse amplifier and white-light-seeded optical parametric amplifiers providing simultaneous passive carrier-envelope phase locking of three ultrashort longwave pulses at the pump, signal, and idler wavelengths corresponding, respectively, to 2.1, 3.5, and 5.2 μm. We also demonstrate bandwidth enhancement and efficient control over nonlinear spectral phase in the regime of cascaded χ2 nonlinearity in ZnGeP2.

Integrity signals

Registry

Crossref · 10.1364/ol.42.000683

Cites

22 of 22 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Current development of high-energy ps Ho:YAG systems will enable scaling MIR lasers up to 10 μm wavelength and beyond.

    “To come full circle and look ahead, the current development of high-energy ps Ho:YAG systems will enable us to further scale these MIR lasers up to 10 μm wavelength and beyond [164].”

    From Roadmap of ultrafast x-ray atomic and molecular physics (2018) · cites this paper as [164]

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Kanai, T., Malevich, P., Kangaparambil, S. S., Ishida, K., Mizui, M., Yamanouchi, K., Hoogland, H., Holzwarth, R., Pugzlys, A., & Baltuska, A.
Affiliations
  • TU Wien (AT)
  • The University of Tokyo (JP)
  • Menlo Systems (Germany) (DE)
Corresponding author
  • Kanai, Tsuneto
  • Malevich, Pavel
  • Kangaparambil, Sarayoo Sasidharan
  • Ishida, Kakuta
  • Mizui, Makoto
  • Yamanouchi, Kaoru
  • Hoogland, Heinar
  • Holzwarth, Ronald
  • Pugzlys, Audrius
Venue
Optics Letters
Published
2017-02-06
Volume
42
Issue
4
Pages
683
ISSN
  • 0146-9592 (ISSN-L)
  • 1539-4794
OpenAlex
W2585468327
Cited by
75
References
22
Citations by year
2026: 1 · 2025: 4 · 2024: 2 · 2023: 7 · 2022: 9 · 2021: 4 · 2020: 11 · 2019: 18 · 2018: 14 · 2017: 5
FWCI
6.44
Type
journal article
Language
en
Open access
closed
Locations
  • Optics Letters (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • Austrian Science Fund (FWF) (F4903-N23, M1884-N27)
  • European Research Council (ERC) (620316)
  • Österreichische Forschungsförderungsgesellschaft (FFG) (E! 6698)
  • Bundesministerium für Bildung und Forschung (BMBF) (E! 6698)
Topics
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Laser-Matter Interactions and Applications
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Photonic Crystal and Fiber Optics
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Fiber Laser Technologies
Keywords
optical parametric amplification, ZnGeP2, mid-infrared pulses, femtosecond pulses, dispersion management, bandwidth enhancement, cascaded second-order nonlinearity

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›