The DOI matches its Crossref record.
Ultra-low-loss optical fiber nanotapers
Open accessAbstract
Optical fiber tapers with a waist size larger than 1microm are commonplace in telecommunications and sensor applications. However the fabrication of low-loss optical fiber tapers with subwavelength diameters was previously thought to be impractical due to difficulties associated with control of the surface roughness and diameter uniformity. In this paper we show that very-long ultra-low-loss tapers can in fact be produced using a conventional fiber taper rig incorporating a simple burner configuration. For single-mode operation, the optical losses we achieve at 1.55microm are one order of magnitude lower than losses previously reported in the literature for tapers of a similar size. SEM images confirm excellent taper uniformity. We believe that these low-loss structures should pave the way to a whole range of fiber nanodevices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Sensitive and Wearable Optical Microfiber Sensor for Human Health Monitoring
Li, J., Chen, J., & Xu, F. (2018) · Advanced Materials Technologies · doi:10.1002/admt.201800296 · Cited by 151
Metadata
- Authors
- Brambilla, G., Finazzi, V., & Richardson, D. J.
- Venue
- Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2004
- Volume
- 12
- Issue
- 10
- Pages
- 2258
- ISSN
- 1094-4087 (ISSN-L)
- OpenAlex
- W2060880308
- Cited by
- 463
- References
- 0
- FWCI
- 19.62
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ultra-low-loss optical fiber nanotapers. https://app.cochat.ai/papers/10.1364/opex.12.002258
- The paper
- Brambilla, G., Finazzi, V., & Richardson, D. J. (2004). Ultra-low-loss optical fiber nanotapers. Optics Express. https://doi.org/10.1364/opex.12.002258
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.