Cited by 151Advanced Fiber Optic SensorsNon-Invasive Vital Sign MonitoringPhotonic Crystal and Fiber Optics

Sensitive and Wearable Optical Microfiber Sensor for Human Health Monitoring

Li, Jin‐hong, Chen, Jin‐hui, Xu, Fei·2018·Advanced Materials Technologies

Abstract

Abstract Silica‐fiber‐based sensors have the advantage of being small, electrically isolated, immune to electromagnetic fields, and easily incorporated into networks. However, only few of them were used for monitoring physiological signals directly, due to their limited sensitivity, comfort, and safety. In this work, a simple architecture for sensitive and wearable photonic sensors, which are capable of strain and pressure detection for healthcare applications is reported. The proposed sensor consists of a hybrid plasmonic microfiber knot resonator embedded in a polydimethylsiloxane membrane. The mechanical sensitivity is more than one order of magnitude larger than exhibited by traditional electronic devices or other fiber devices, including Bragg gratings. In addition, the sensing of wrist pulse, respiration, and finger pulse are also experimentally demonstrated. This novel photonic‐based platform may provide a new basis for designing sensitive and wearable sensors for personalized diagnostics and physiological monitoring applications. With their potential to be embedded into networks of smart clothing and remote health monitoring of patients, these sensors possessing great biocompatibility will have a distinguished advantage in military, aerospace, and medical applications, particularly in high‐magnetic‐field environments, e.g., magnetic resonance imaging.

Integrity signals

Registry

Crossref · 10.1002/admt.201800296

Cites

35 of 35 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • A hybrid plasmonic microfiber knot resonator embedded in a PDMS membrane has high sensitivity for sensing wrist/finger pulse and respiration.

    “In addition, experiments with a novel photonic-based platform—a hybrid plasmonic microfiber knot resonator embedded in a PDMS membrane—were performed and high sensitivity was confirmed when sensing wrist/finger pulse and respiration [216].”

    From The Current State of Optical Sensors in Medical Wearables (2022) · cites this paper as [216]

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Li, J., Chen, J., & Xu, F.
Affiliations
  • National Laboratory of Solid State Microstructures College of Engineering and Applied Sciences and Collaborative Innovation Center of Advanced Microstructures Nanjing University Nanjing 210093 P. R. China
  • Collaborative Innovation Center of Advanced Microstructures (CN)
Corresponding author
Xu, Fei
ORCID
Xu, Fei
Venue
Advanced Materials Technologies
Publisher
Wiley
Published
2018-10-03
Volume
3
Issue
12
ISSN
2365-709X (ISSN-L)
OpenAlex
W2894770852
Cited by
151
References
35
Citations by year
2026: 12 · 2025: 22 · 2024: 38 · 2023: 26 · 2022: 17 · 2021: 19 · 2020: 8 · 2019: 8 · 2018: 1
FWCI
3.44
Type
journal article
Language
en
Open access
closed
Locations
Advanced Materials Technologies (publishedVersion)
Funders
National Natural Science Foundation of China (61535005, 61475069)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced Fiber Optic Sensors
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Photonic Crystal and Fiber Optics
Keywords
wearable sensors, polydimethylsiloxane membranes, strain sensing, pressure sensing, physiological monitoring, pulse detection, respiratory monitoring, smart clothing, remote patient monitoring, magnetic resonance imaging safety, biocompatibility

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review