Efficient concentration of high-energy x-rays for diffraction-limited imaging resolution
Open accessThe DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
Newly available x-ray nanobeams in synchrotron radiation facilities open new research avenues in the nanosciences. However, a significant challenge is to efficiently concentrate, particularly for high-energy x-rays, a large photon flux into a very small focal spot. Here, we demonstrate for the first time, to the best of our knowledge, a sub-13-nm (FWHM) diffraction-limited x-ray focus size with 6 billion photons per second formed using elliptically figured mirrors operating at 33.6 keV. This is the smallest and brightest focus spot in this high-energy range. We report the results of an x-ray ptychography experiment to characterize the wavefront at the focus position. This offers new opportunities in multidisciplinary fields for x-ray microscopy techniques in which the focal spot size limits the resolution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hell, S. W. (2007) · Science · doi:10.1126/science.1137395 · Cited by 2,967
Formation of Optical Images by X-Rays
Kirkpatrick, P. H., & Baez, A. V. (1948) · Journal of the Optical Society of America · doi:10.1364/josa.38.000766 · Cited by 1,396
High-Resolution Scanning X-ray Diffraction Microscopy
Thibault, P., Dierolf, M., Menzel, A., Bunk, O., David, C., & Pfeiffer, F. (2008) · Science · doi:10.1126/science.1158573 · Cited by 1,321
A compound refractive lens for focusing high-energy X-rays
Snigirev, A., Kohn, V., Snigireva, I., & Lengeler, B. (1996) · Nature · doi:10.1038/384049a0 · Cited by 1,062
Movable Aperture Lensless Transmission Microscopy: A Novel Phase Retrieval Algorithm
Faulkner, H. M. L., & Rodenburg, J. M. (2004) · Physical Review Letters · doi:10.1103/physrevlett.93.023903 · Cited by 839
Sakdinawat, A., & Attwood, D. (2010) · Nature Photonics · doi:10.1038/nphoton.2010.267 · Cited by 728
Probe retrieval in ptychographic coherent diffractive imaging
Thibault, P., Dierolf, M., Bunk, O., Menzel, A., & Pfeiffer, F. (2009) · Ultramicroscopy · doi:10.1016/j.ultramic.2008.12.011 · Cited by 717
Breaking the 10 nm barrier in hard-X-ray focusing
Mimura, H., Handa, S., Kimura, T., Yumoto, H., Yamakawa, D., Yokoyama, H., Matsuyama, S., Inagaki, K., Yamamura, K., Sano, Y., et al. (2010) · Nature Physics · doi:10.1038/nphys1457 · Cited by 552
Choice of clip levels for beam width measurements using knife-edge techniques
Siegman, A. E., Sasnett, M. W., & Johnston, T. F. (1991) · IEEE Journal of Quantum Electronics · doi:10.1109/3.83346 · Cited by 212
Unconventional methods of imaging: computational microscopy and compact implementations
McLeod, E. J., & Özcan, A. (2016) · Reports on Progress in Physics · doi:10.1088/0034-4885/79/7/076001 · Cited by 129
Ptychography with broad-bandwidth radiation
Enders, B., Dierolf, M., Cloetens, P., Stockmar, M. K., Pfeiffer, F., & Thibault, P. (2014) · Applied Physics Letters · doi:10.1063/1.4874304 · Cited by 97
Self-citationElementary signals in ptychography
da Silva, J. C., & Menzel, A. (2015) · Optics Express · doi:10.1364/oe.23.033812 · Cited by 79
3D chemical imaging based on a third-generation synchrotron source
Bleuet, P., Gergaud, P., Lemelle, L., Tucoulou, R., Cloetens, P., Susini, J., Delette, G., & Simionovici, A. (2010) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2010.02.011 · Cited by 52
Self-citationSoft X‐ray spectromicroscopy for speciation, quantitation and nano‐eco‐toxicology of nanomaterials
Lawrence, J. R., Swerhone, G. D. W., Dynes, J. J., Korber, D. R., & Hitchcock, A. P. (2014) · Journal of Microscopy · doi:10.1111/jmi.12156 · Cited by 25
Cited by
Tan, S., Shadike, Z., Li, J., Wang, X., Yang, Y., Lin, R., Cresce, A., Hu, J., Hunt, A., Waluyo, I., et al. (2022) · Nature Energy · doi:10.1038/s41560-022-01020-x · Cited by 414
Self-citationHeterogeneous damage in Li-ion batteries: Experimental analysis and theoretical modeling
Xu, R., Yang, Y., Yin, F., Liu, P., Cloetens, P., Liu, Y., Lin, F., & Zhao, K. (2019) · Journal of the Mechanics and Physics of Solids · doi:10.1016/j.jmps.2019.05.003 · Cited by 345
Self-citationJiang, Z., Li, J., Yang, Y., Mu, L., Wei, C., Yu, X., Pianetta, P., Zhao, K., Cloetens, P., Lin, F., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-16233-5 · Cited by 261
Self-citationQuantification of Heterogeneous Degradation in Li‐Ion Batteries
Yang, Y., Xu, R., Zhang, K., Lee, S., Mu, L., Liu, P., Waters, C. K., Spence, S., Xu, Z., Wei, C., et al. (2019) · Advanced Energy Materials · doi:10.1002/aenm.201900674 · Cited by 247
Self-citationDynamics of particle network in composite battery cathodes
Li, J., Sharma, N., Jiang, Z., Yang, Y., Monaco, F., Xu, Z., Hou, D., Ratner, D., Pianetta, P., Cloetens, P., et al. (2022) · Science · doi:10.1126/science.abm8962 · Cited by 220
Self-citation
Metadata
- Authors
- Cesar da Silva, J., Pacureanu, A., Yang, Y., Bohic, S., Morawe, C., Barrett, R., & Cloetens, P.
- Venue
- Optica
- Publisher
- Optica Publishing Group
- Published
- 2017-04-24
- Volume
- 4
- Issue
- 5
- Pages
- 492
- ISSN
- 2334-2536 (ISSN-L)
- OpenAlex
- W2607168317
- Cited by
- 209
- References
- 14
- FWCI
- 28.70
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.