Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 319

The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.

Octave-spanning dissipative Kerr soliton frequency combs in Si_3N_4 microresonators

Open access
Pfeiffer, Martin H. P., Herkommer, Clemens, Liu, Junqiu, Guo, Hairun, Karpov, Maxim, Lucas, Erwan, Zervas, Michael, Kippenberg, Tobias J.·2017·Optica

Abstract

Octave-spanning, self-referenced frequency combs are applied in diverse fields ranging from precision metrology to astrophysical spectrometer calibration. In the past decade, Kerr frequency comb generators have emerged as alternative scheme offering chip-scale integration, high repetition rate and bandwidths that are only limited by group velocity dispersion. The recent observation of Kerr frequency combs operating in the dissipative Kerr soliton (DKS) regime, along with dispersive wave formation, has provided the means for fully coherent, broadband Kerr frequency comb generation with engineered spectral envelope. Here, by carefully optimizing the photonic Damascene fabrication process, and dispersion engineering of $\mathrm{Si_{3}N_{4}}$ microresonators with $1\,\mathrm{THz}$ free spectral range, we achieve bandwidths exceeding one octave at low powers ($\mathcal{O}(100\,\mathrm{mW})$) for pump lasers residing in the telecom C-band ($1.55\,\mathrm{μm}$), as well as for the first time in the O-band ($1.3\,\mathrm{μm}$). Equally important, we find that for THz repetition rate comb states, conventional criteria applied to identify DKS comb states fail. Investigating the coherence of generated, octave-spanning Kerr comb states we unambiguously identify DKS states using a response measurement. This allows to demonstrate octave-spanning DKS comb states at both pump laser wavelengths of $1.3\mathrm{\,μm}$ and $1.55\,\mathrm{μm}$ including the broadest DKS state generated to date, spanning more than $200\,\mathrm{THz}$ of optical bandwidth. Octave spanning DKS frequency combs can form essential building blocks for metrology or spectroscopy, and their operation at $1.3\mathrm{\,μm}$ enables applications in life sciences such as Kerr comb based optical coherence tomography or dual comb coherent antistokes Raman scattering.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1364/optica.4.000684

Cites

31 of 31 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 31 references

Cited by

See all 319

Metadata

Authors
Pfeiffer, M. H. P., Herkommer, C., Liu, J., Guo, H., Karpov, M., Lucas, E., Zervas, M., & Kippenberg, T. J.
Venue
Optica
Published
2017-06-22
Volume
4
Issue
7
Pages
684
ISSN
2334-2536 (ISSN-L)
OpenAlex
W2583548722
Cited by
319
References
31
FWCI
15.37
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Octave-spanning dissipative Kerr soliton frequency combs in Si_3N_4 microresonators. https://app.cochat.ai/papers/10.1364/optica.4.000684
The paper
Pfeiffer, M. H. P., Herkommer, C., Liu, J., Guo, H., Karpov, M., Lucas, E., Zervas, M., & Kippenberg, T. J. (2017). Octave-spanning dissipative Kerr soliton frequency combs in Si_3N_4 microresonators. Optica. https://doi.org/10.1364/optica.4.000684

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.