Simultaneous spatial, spectral, and 3D compressive imaging via efficient Fourier single-pixel measurements
Open accessThe DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
Single-pixel imaging can capture images using a detector without spatial resolution, which enables imaging in various situations that are challenging or impossible with conventional pixelated detectors. Here we report a compressive single-pixel imaging approach that can simultaneously encode and recover spatial, spectral, and 3D information of the object. In this approach, we modulate and condense the object information in the Fourier space and detect the light signals using a single-pixel detector. The data-compressing operation is similar to conventional compression algorithms that selectively store the largest coefficients of a transform domain. In our implementation, we selectively sample the largest Fourier coefficients, and no iterative optimization process is needed in the recovery process. We demonstrate an 88% compression ratio for producing a high-quality full-color 3D image. The reported approach provides a solution for information multiplexing in single-pixel imaging settings. It may also generate new insights for developing multi-modality computational imaging systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Image quality assessment: from error visibility to structural similarity
Wang, Z., Bovik, A. C., Sheikh, H. R., & Simoncelli, E. P. (2004) · IEEE Transactions on Image Processing · doi:10.1109/tip.2003.819861 · Cited by 57,892
Single-pixel imaging via compressive sampling
Duarte, M. F., Davenport, M. A., Takhar, D., Laska, J. N., Sun, T., Kelly, K. F., & Baraniuk, R. G. (2008) · IEEE Signal Processing Magazine · doi:10.1109/msp.2007.914730 · Cited by 3,575
The JPEG still picture compression standard
Wallace, G. K. (1992) · IEEE Transactions on Consumer Electronics · doi:10.1109/30.125072 · Cited by 2,851
Fourier transform profilometry for the automatic measurement of 3-D object shapes
Takeda, M., & Mutoh, K. (1983) · Applied Optics · doi:10.1364/ao.22.003977 · Cited by 1,855
Shapiro, J. H. (2008) · Physical Review A · doi:10.1103/physreva.78.061802 · Cited by 1,531
3D Computational Imaging with Single-Pixel Detectors
Sun, B., Edgar, M., Bowman, R. W., Vittert, L., Welsh, S. S., BOWMAN, A. W., & Padgett, M. J. (2013) · Science · doi:10.1126/science.1234454 · Cited by 914
Single-pixel imaging by means of Fourier spectrum acquisition
Zhang, Z., Ma, X., & Zhong, J. (2015) · Nature Communications · doi:10.1038/ncomms7225 · Cited by 791
Self-citationSingle-pixel three-dimensional imaging with time-based depth resolution
Sun, M.-J., Edgar, M., Gibson, G. M., Sun, B., Radwell, N., Lamb, R., & Padgett, M. J. (2016) · Nature Communications · doi:10.1038/ncomms12010 · Cited by 626
Fast full-color computational imaging with single-pixel detectors
Welsh, S. S., Edgar, M., Bowman, R. W., Jonathan, P., Sun, B., & Padgett, M. J. (2013) · Optics Express · doi:10.1364/oe.21.023068 · Cited by 292
Multispectral imaging using a single bucket detector
Bian, L., Suo, J., Situ, G., Li, Z., Fan, J., Chen, F., & Dai, Q. (2016) · Scientific Reports · doi:10.1038/srep24752 · Cited by 213
Cited by
Principles and prospects for single-pixel imaging
Edgar, M. P., Gibson, G. M., & Padgett, M. J. (2019) · Nature Photonics · doi:10.1038/s41566-018-0300-7 · Cited by 1,029
Real-time terahertz imaging with a single-pixel detector
Stantchev, R. I., Yu, X., Blu, T., & Pickwell-MacPherson, E. (2020) · Nature Communications · doi:10.1038/s41467-020-16370-x · Cited by 492
Metadata
- Authors
- Zhang, Z., Liu, S., Peng, J., Yao, M., Zheng, G., & Zhong, J.
- Venue
- Optica
- Publisher
- Optica Publishing Group
- Published
- 2018-03-20
- Volume
- 5
- Issue
- 3
- Pages
- 315
- ISSN
- 2334-2536 (ISSN-L)
- OpenAlex
- W2794318235
- Cited by
- 201
- References
- 15
- FWCI
- 6.23
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.