CoChat

Regional trace-gas source attribution using a field-deployed dual frequency comb spectrometer

Open access
Coburn, Sean, Alden, Caroline B., Wright, Robert, Cossel, Kevin, Baumann, Esther, Truong, Gar-Wing, Giorgetta, Fabrizio, Sweeney, Colm, Newbury, Nathan R., Prasad, Kuldeep, Coddington, Ian, Rieker, Gregory B. · 2018 · Optica
Cited by 204

The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.

Abstract

Identification and quantification of trace-gas sources is a major challenge for understanding and regulating air quality and greenhouse gas emissions. Current approaches provide either continuous but localized monitoring, or quasi-instantaneous "snapshot-in-time" regional monitoring. There is a need for emissions detection that provides both continuous and regional coverage, because sources and sinks can be episodic and spatially variable. We field deploy a dual frequency comb laser spectrometer for the first time, enabling an observing system that provides continuous detection of trace-gas sources over multiple-square-kilometer regions. Field tests simulating methane emissions from oil and gas production demonstrate detection and quantification of a 1.6 g min(-1) source (less than the average emissions from a small pneumatic controller) from a distance of 1 kin, and the ability to discern two leaks among a field of many potential sources. The technology achieves the goal of detecting, quantifying, and attributing emissions sources continuously through time, over large areas, and at emissions rates similar to 1000 x lower than current regional approaches. It therefore provides a useful tool for monitoring and mitigating undesirable sources and doses a major information gap in the atmospheric sciences. (C) 2018 Optical Society of America under the terms of the OSA Open Access Publishing Agreement

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1364/optica.5.000320

Cites

33 of 33 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 33 references

Cited by

See all 204

Metadata

Authors
Coburn, S., Alden, C. B., Wright, R., Cossel, K., Baumann, E., Truong, G.-W., Giorgetta, F., Sweeney, C., Newbury, N. R., Prasad, K., Coddington, I., & Rieker, G. B.
Venue
Optica
Published
2018-03-22
Volume
5
Issue
4
Pages
320
ISSN
2334-2536 (ISSN-L)
OpenAlex
W2790969565
Cited by
204
References
33
FWCI
10.18
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Regional trace-gas source attribution using a field-deployed dual frequency comb spectrometer. https://app.cochat.ai/papers/10.1364/optica.5.000320
The paper
Coburn, S., Alden, C. B., Wright, R., Cossel, K., Baumann, E., Truong, G.-W., Giorgetta, F., Sweeney, C., Newbury, N. R., Prasad, K., Coddington, I., & Rieker, G. B. (2018). Regional trace-gas source attribution using a field-deployed dual frequency comb spectrometer. Optica. https://doi.org/10.1364/optica.5.000320

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.