Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 247

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Sub-milliwatt-level microresonator solitons with extended access range using an auxiliary laser

Open access
Zhang, Shuangyou, Silver, Jonathan M., Del Bino, Leonardo, Copie, Francois, Woodley, Michael T. M., Ghalanos, George N., Svela, Andreas Ø., Moroney, Niall, Del’Haye, Pascal · 2019 · Optica

Abstract

The recent demonstration of dissipative Kerr solitons in microresonators has opened a new pathway for the generation of ultrashort pulses and low-noise frequency combs with gigahertz to terahertz repetition rates, enabling applications in frequency metrology, astronomy, optical coherent communications, and laser-based ranging. A main challenge for soliton generation, in particular in ultra-high-Q resonators, is the sudden change of circulating intracavity power during the onset of soliton generation. This sudden power change requires precise control of the seed laser frequency and power or fast control of the resonator temperature. Here, we report a robust and simple way to increase the stability range of the soliton regime by using an auxiliary laser that passively stabilizes the intracavity power. In our experiments with fused silica resonators, we are able to extend the pump laser frequency stability range of microresonator solitons by two orders of magnitude, which enables soliton generation by slow and manual tuning of the pump laser into resonance and at unprecedented low power levels. Both single- and multi-soliton mode-locked states are generated in a 1.3-mm-diameter fused silica microrod resonator with a free spectral range of ~50.6 GHz, at a 1554 nm pump wavelength at threshold powers <3 mW. Moreover, with a smaller 230-{\mu}m-diameter microrod, we demonstrate soliton generation at 780 {\mu}W threshold power. The passive enhancement of the stability range of microresonator solitons paves the way for robust and low threshold microcomb systems with substantially relaxed stability requirements for the pump laser source. In addition, this method could be useful in a wider range of microresonator applications that require reduced sensitivity to external perturbations.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1364/optica.6.000206

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 247

Metadata

Authors
Zhang, S., Silver, J. M., Del Bino, L., Copie, F., Woodley, M. T. M., Ghalanos, G. N., Svela, A. Ø., Moroney, N., & Del’Haye, P.
Venue
Optica
Published
2019-02-19
Volume
6
Issue
2
Pages
206
ISSN
2334-2536 (ISSN-L)
OpenAlex
W2911741796
Cited by
247
References
3
FWCI
11.37
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Sub-milliwatt-level microresonator solitons with extended access range using an auxiliary laser. https://app.cochat.ai/papers/10.1364/optica.6.000206
The paper
Zhang, S., Silver, J. M., Del Bino, L., Copie, F., Woodley, M. T. M., Ghalanos, G. N., Svela, A. Ø., Moroney, N., & Del’Haye, P. (2019). Sub-milliwatt-level microresonator solitons with extended access range using an auxiliary laser. Optica. https://doi.org/10.1364/optica.6.000206

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.