Fluorescence Intensity Calibration Using the Raman Scatter Peak of Water
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Fluorescence data of replicate samples obtained from different fluorescence spectrometers or by the same spectrometer but with different instrument settings can have great intensity differences. In order to compare such data an intensity calibration must be applied. Here we explain a simple calibration method for fluorescence intensity using only the integrated area of a water Raman peak. By applying this method to data from three different instruments, we show that it is possible to remove instrument-dependent intensity factors, and we present results on a unified scale of Raman units. The method presented is a rapid and simple approach suitable for routine measurements with no need for hazardous chemicals.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of Fluorescence Spectroscopy
Lakowicz, J. R. (1999) · Springer eBooks · doi:10.1007/978-1-4757-3061-6 · Cited by 26,947
Principles of Fluorescence Spectroscopy
(2006) · Springer eBooks · doi:10.1007/978-0-387-46312-4 · Cited by 19,339
Stedmon, C. A., Markager, S., & Bro, R. (2003) · Marine Chemistry · doi:10.1016/s0304-4203(03)00072-0 · Cited by 2,019
Self-citationCharacterization of dissolved organic matter in the Black Sea by fluorescence spectroscopy
Coble, P. G., Green, S. A., Blough, N. V., & Gagosian, R. B. (1990) · Nature · doi:10.1038/348432a0 · Cited by 673
Multivariate Autofluorescence of Intact Food Systems
Christensen, J., Nørgaard, L., Bro, R., & Engelsen, S. B. (2006) · Chemical Reviews · doi:10.1021/cr050019q · Cited by 317
Mapping of the total fluorescence of human blood serum as a new method for its characterization
Wolfbeis, O. S., & Leiner, M. J. P. (1985) · Analytica Chimica Acta · doi:10.1016/s0003-2670(00)84422-0 · Cited by 128
Wavelength dependence of the Raman cross section for liquid water
Faris, G. W., & Copeland, R. A. (1997) · Applied Optics · doi:10.1364/ao.36.002686 · Cited by 86
Qualification of a fluorescence spectrometer for measuring true fluorescence spectra
DeRose, P. C., Early, E. A., & Kramer, G. W. (2007) · Review of Scientific Instruments · doi:10.1063/1.2715952 · Cited by 76
DeRose, P. C., Smith, M. V., Mielenz, K. D., Blackburn, D. H., & Kramer, G. W. (2007) · Journal of Luminescence · doi:10.1016/j.jlumin.2007.08.003 · Cited by 32
Cited by
Murphy, K. R., Butler, K. D., Spencer, R. G. M., Stedmon, C. A., Boehme, J. R., & Aiken, G. R. (2010) · Environmental Science & Technology · doi:10.1021/es102362t · Cited by 753
Self-citationShutova, Y., Baker, A., Bridgeman, J., & Henderson, R. K. (2014) · Water Research · doi:10.1016/j.watres.2014.01.053 · Cited by 438
Jørgensen, L., Stedmon, C. A., Kragh, T., Markager, S., Middelboe, M., & Søndergaard, M. (2011) · Marine Chemistry · doi:10.1016/j.marchem.2011.05.002 · Cited by 399
Self-citationLee, Y. K., Murphy, K. R., & Hur, J. (2020) · Environmental Science & Technology · doi:10.1021/acs.est.0c00942 · Cited by 380
Inner filter correction of dissolved organic matter fluorescence
Kothawala, D. N., Murphy, K. R., Stedmon, C. A., Weyhenmeyer, G. A., & Tranvik, L. J. (2013) · Limnology and Oceanography: Methods · doi:10.4319/lom.2013.11.616 · Cited by 373
Self-citation
Metadata
- Authors
- Lawaetz, A. J., & Stedmon, C. A.
- Venue
- Applied Spectroscopy
- Publisher
- SAGE Publications
- Published
- 2009-08
- Volume
- 63
- Issue
- 8
- Pages
- 936-940
- ISSN
- 0003-7028 (ISSN-L)
- 1943-3530
- OpenAlex
- W1999760584
- Cited by
- 1,151
- References
- 9
- FWCI
- 7.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.