The DOI matches its Crossref record.
Inner filter correction of dissolved organic matter fluorescence
Abstract
The fluorescence of dissolved organic matter (DOM) is suppressed by a phenomenon of self‐quenching known as the inner filter effect (IFE). Despite widespread use of fluorescence to characterize DOM in surface waters, the advantages and constraints of IFE correction are poorly defined. We assessed the effectiveness of a commonly used absorbance‐based approach (ABA), and a recently proposed controlled dilution approach (CDA) to correct for IFE. Linearity between corrected fluorescence and total absorbance (A Total ; the sum of absorbance at excitation and emission wavelengths) across the full excitation‐emission matrix (EEM) in dilution series of four samples indicated both ABA and CDA were effective to an absorbance of at least 1.5 in a 1 cm cell, regardless of wavelength positioning. In regions of the EEMs where signal to background noise (S/N) was low, CDA correction resulted in more variability than ABA correction. From the ABA algorithm, the onset of significant IFE (>5%) occurs when absorbance exceeds 0.042. In these cases, IFE correction is required, which was the case for the vast majority (97%) of lakes in a nationwide survey (n= 554). For highly absorbing samples, undesirably large dilution factors would be necessary to reduce absorbance below 0.042. For rare EEMs with A Total > 1.5 (3.0% of the lakes in the Swedish survey), a 2‐fold dilution is recommended followed by ABA or CDA correction. This study shows that for the vast majority of natural DOM samples the most commonly applied ABA algorithm provides adequate correction without prior dilution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Fluorescence spectroscopy for wastewater monitoring: A review
Carstea, E. M., Bridgeman, J., Baker, A., & Reynolds, D. M. (2016) · Water Research · doi:10.1016/j.watres.2016.03.021 · Cited by 666
Inner filter effect in fluorescence spectroscopy: As a problem and as a solution
Kumar Panigrahi, S., & Kumar Mishra, A. (2019) · Journal of Photochemistry and Photobiology C: Photochemistry Reviews · doi:10.1016/j.jphotochemrev.2019.100318 · Cited by 485
Controls of dissolved organic matter quality: evidence from a large‐scale boreal lake survey
Kothawala, D. N., Stedmon, C. A., Müller, R. A., Weyhenmeyer, G. A., Köhler, S. J., & Tranvik, L. J. (2014) · Global Change Biology · doi:10.1111/gcb.12488 · Cited by 396
Self-citationShi, W., Zhuang, W.-E., Hur, J., & Yang, L. (2021) · Water Research · doi:10.1016/j.watres.2020.116406 · Cited by 299
Lavonen, E. E., Kothawala, D. N., Tranvik, L. J., Gonsior, M., Schmitt-Kopplin, P., & Köhler, S. J. (2015) · Water Research · doi:10.1016/j.watres.2015.08.024 · Cited by 274
Self-citation
Metadata
- Authors
- Kothawala, D. N., Murphy, K. R., Stedmon, C. A., Weyhenmeyer, G. A., & Tranvik, L. J.
- Venue
- Limnology and Oceanography: Methods
- Publisher
- Wiley
- Published
- 2013-12
- Volume
- 11
- Issue
- 12
- Pages
- 616-630
- ISSN
- 1541-5856 (ISSN-L)
- OpenAlex
- W1926401635
- Cited by
- 373
- References
- 0
- FWCI
- 7.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Inner filter correction of dissolved organic matter fluorescence. https://app.cochat.ai/papers/10.4319/lom.2013.11.616
- The paper
- Kothawala, D. N., Murphy, K. R., Stedmon, C. A., Weyhenmeyer, G. A., & Tranvik, L. J. (2013). Inner filter correction of dissolved organic matter fluorescence. Limnology and Oceanography: Methods. https://doi.org/10.4319/lom.2013.11.616
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.