The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Improved Sensitivity of Infrared Spectroscopy by the Application of Least Squares Methods
Abstract
Improved sensitivity and precision in the quantitative analysis of trace gases by Fourier transform infrared spectroscopy have been achieved by the application of new spectral least squares methods. By relating all of the spectral information present in the reference spectrum of a trace gas to that of the unknown sample and by appropriately fitting the baseline, detections of trace gases can be obtained even though the individual spectral features may lie well below the noise level. Four least squares methods incorporating different baseline assumptions were investigated and compared using calibrated gases of CO, N 2 O, and CO 2 in dry air. These methods include: (I) baseline known, (II) baseline linear over the spectral region of interest, (III) baseline linear over each spectral peak, and (IV) negligible baseline shift between successive data points. Methods III and IV were found to be most reliable for the gases studied. When method III is applied to the spectra of these trace gases, detection limits improved by factors of 5 to 7 over conventional methods applied to the same data. “Three sigma” detection limits are equal to 0.6, 0.2, and 0.08 ppm for CO, N 2 O, and CO 2, respectively, when a 10-cm pathlength at a total pressure of 640 Torr is used with a ∼35 min measurement time at 0.06 cm−1 resolution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intensities and Shapes of Infrared Absorption Bands of Substances in the Liquid Phase
Ramsay, D. A. (1952) · Journal of the American Chemical Society · doi:10.1021/ja01121a018 · Cited by 673
Cited by
Haaland, D. M., & Thomas, E. V. (1988) · Analytical Chemistry · doi:10.1021/ac00162a020 · Cited by 2,539
Self-citationZavaleta, C. L., Smith, B. R., Walton, I., Doering, W., Davis, G., Shojaei, B., Natan, M. J., & Gambhir, S. S. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0813327106 · Cited by 714
Noninvasive molecular imaging of small living subjects using Raman spectroscopy
Keren, S., Zavaleta, C., Cheng, Z., de la Zerda, A., Gheysens, O., & Gambhir, S. S. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0710575105 · Cited by 604
Davis, R. M., Campbell, J. L., Burkitt, S., Qiu, Z., Kang, S., Mehraein, M., Miyasato, D., Salinas, H., Liu, J. T. C., & Zavaleta, C. (2018) · Nanomaterials · doi:10.3390/nano8110953 · Cited by 60
Metadata
- Authors
- Haaland, D. M., & Easterling, R. G.
- Venue
- Applied Spectroscopy
- Publisher
- SAGE Publications
- Published
- 1980-09
- Volume
- 34
- Issue
- 5
- Pages
- 539-548
- ISSN
- 0003-7028 (ISSN-L)
- 1943-3530
- OpenAlex
- W2009889695
- Cited by
- 158
- References
- 1
- FWCI
- 1.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Improved Sensitivity of Infrared Spectroscopy by the Application of Least Squares Methods. https://app.cochat.ai/papers/10.1366/0003702804731258
- The paper
- Haaland, D. M., & Easterling, R. G. (1980). Improved Sensitivity of Infrared Spectroscopy by the Application of Least Squares Methods. Applied Spectroscopy. https://doi.org/10.1366/0003702804731258
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.