Second Derivative Infrared Spectroscopy
Abstract
The analysis of trace gases by infrared spectroscopy is enhanced by computing the second derivative of the spectrum. The peak maxima are increased for sharp bands while contributions from broad, structureless, continua are reduced. For weak absorbers the peak maxima are linear in concentration. The advantages of second derivative infrared spectroscopy in trace gas analysis are illustrated, and an algorithm is described for numerical differentiation of a digitized infrared spectrum.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Second derivative analysis of FTIR absorption spectra resolved overlapping bands, removed baseline errors, identified small adjacent bands, and enabled quantitative analysis.
“Second derivatives resolved the overlapping bands in the raw spectra, removed the baseline errors and lead to the identification of small and adjacent absorption bands and enabled quantitative analysis [26,49].”
From Biomolecular transitions and lipid accumulation in green microalgae monitored by FTIR and Raman analysis (2020) · cites this paper as [49]
Cites
High sensitivity pollution detection employing tunable diode lasers
Reid, J., Shewchun, J., Garside, B. K., et al. (1978) · Applied Optics · doi:10.1364/ao.17.000300 · Cited by 182 · see citing works
Wavelength Standards in the Infrared
(1966) · Elsevier eBooks · doi:10.1016/b978-0-12-395742-9.x5001-6 · Cited by 65 · see citing works
Determination of Reaction Rates by the Use of Cubic Spline Interpolation
Dunfield, L. G., & Read, J. F. (1972) · The Journal of Chemical Physics · doi:10.1063/1.1678550 · Cited by 24 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Rieppo, L., Saarakkala, S., Närhi, T., Helminen, H. J., Jurvelin, J. S., & Rieppo, J. (2012) · Osteoarthritis and Cartilage · doi:10.1016/j.joca.2012.01.010 · Cited by 254 · see citing works
Grace, C. E. E., Lakshmi, P. K., Meenakshi, S., Vaidyanathan, S., Srisudha, S., & Mary, M. B. (2020) · Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2019.117382 · Cited by 104 · see citing works
Esther Elizabeth Grace, C., Briget Mary, M., Vaidyanathan, S., & Srisudha, S. (2022) · Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2021.120830 · Cited by 21 · see citing works
- Authors
- Whitbeck, M. R.
- Affiliations
- General Motors (United States) (US)
- Corresponding author
- Whitbeck, Michael R.
- Venue
- Applied Spectroscopy
- Publisher
- SAGE Publications
- Published
- 1981-01
- Volume
- 35
- Issue
- 1
- Pages
- 93-95
- ISSN
- 0003-7028 (ISSN-L)
- 1943-3530
- OpenAlex
- W2087177336
- Cited by
- 57
- References
- 3
- Citations by year
- 2025: 4 · 2024: 3 · 2023: 2 · 2022: 9 · 2021: 5 · 2020: 2 · 2019: 4 · 2017: 3 · 2016: 2 · 2015: 1 · 2014: 1 · 2012: 2
- FWCI
- 1.02
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Applied Spectroscopy (publishedVersion)
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Spectroscopy and Laser Applications
- Physical Sciences › Chemistry › Analytical Chemistry › Spectroscopy and Chemometric Analyses
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
- Keywords
- second derivative infrared spectroscopy, trace gas analysis, numerical differentiation, continuum subtraction
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review