Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 680

The DOI matches its Crossref record.

Infrared Intensities of Liquids XX: The Intensity of the OH Stretching Band of Liquid Water Revisited, and the Best Current Values of the Optical Constants of H2O(l) at 25°C between 15,000 and 1 cm−1

Bertie, John E., Lan, Zhida·1996·Applied Spectroscopy

Abstract

The previously reported nonreproducibility of the intensity of the OH stretching band of liquid water has been explored. It was found that it can be eliminated in measurements with the Circle® multiple ATR cell by ensuring that the ATR rod is coaxial with the glass liquid holder. It was also found that normal laboratory temperature variations of a few degrees change the intensity by ⩽∼1% of the peak height. A new imaginary refractive index spectrum of water has been determined between 4000 and 700 cm 1 as the average of spectra calculated from ATR spectra recorded by four workers in our laboratory over the past seven years. It was obtained under experimental and computational conditions superior to those used previously, but is only marginally different from the spectra reported in 1989. In particular, the integrated intensities of the fundamentals are not changed significantly from those reported in 1989. The available imaginary refractive index, k, values between 15,000 and 1 cm−1 have been compared. The values that are judged to be the most reliable have been combined into a recommended k spectrum of H 2 O(l) at 25 °C between 15,000 and 1 cm−1, from which the real refractive index spectrum has been calculated by Kramers–Kronig transformation. The recommended values of the real and imaginary refractive indices and molar absorption coefficients of liquid water at 25 ± 1 °C are presented in graphs and tables. The real and imaginary dielectric constants and the real and imaginary molar polarizabilities in this wavenumber range can be calculated from the tables. Conservatively estimated probable errors of the recommended k values are given. The precision with which the values can be measured in one laboratory and the relative errors between regions are, of course, far smaller than these probable errors. The recommended k values should be of considerable value as interim standard intensities of liquid water, which will facilitate the transfer of intensities between laboratories.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1366/0003702963905385

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 680

Metadata

Authors
Bertie, J. E., & Lan, Z.
Venue
Applied Spectroscopy
Published
1996-08
Volume
50
Issue
8
Pages
1047-1057
ISSN
  • 0003-7028 (ISSN-L)
  • 1943-3530
OpenAlex
W2114722820
Cited by
680
References
0
FWCI
3.12
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Infrared Intensities of Liquids XX: The Intensity of the OH Stretching Band of Liquid Water Revisited, and the Best Current Values of the Optical Constants of H2O(l) at 25°C between 15,000 and 1 cm−1. https://app.cochat.ai/papers/10.1366/0003702963905385
The paper
Bertie, J. E., & Lan, Z. (1996). Infrared Intensities of Liquids XX: The Intensity of the OH Stretching Band of Liquid Water Revisited, and the Best Current Values of the Optical Constants of H2O(l) at 25°C between 15,000 and 1 cm−1. Applied Spectroscopy. https://doi.org/10.1366/0003702963905385

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.