Near-Infrared Spectroscopic Determination of Acetate, Ammonium, Biomass, and Glycerol in an Industrial Escherichia Coli Fermentation
The DOI matches its Crossref record.
Abstract
By use of near-infrared (NIR) spectroscopy, simultaneous, multiple-constituent estimation of important bioprocess parameters can be obtained in a time frame (<1 min assay) that was previously unattainable. Therefore, with NIR spectroscopy the opportunity exists to incorporate real-time chemical information into bioprocess monitoring or control strategies which will lead to significant bioprocess improvements. The NIR spectroscopic analysis of unmodified whole broth samples for acetate, ammonium, biomass, and glycerol is described for an industrial Escherichia coli fed-batch fermentation bioprocess. For acetate and glycerol, suitable results were obtained from multiple linear least-squares regression (MLR) analysis. A more sophisticated partial least-squares (PLS) regression analysis was necessary to adequately model ammonium and biomass. The respective prediction errors (1σ) of 0.7 g/L, 1.4 g/L, 0.7 g/L, and 7 mmol/L for acetate, biomass, glycerol, and ammonium compare well with the error of the wet chemical reference methods used to derive the calibration algorithms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Optimization and scale up of industrial fermentation processes
Schmidt, F. R. (2005) · Applied Microbiology and Biotechnology · doi:10.1007/s00253-005-0003-0 · Cited by 362
“…at 350 nm and the fluorescence measurements at 450 nm (more details and literature in Vaidyanathan 1999); (2) near-infrared spectroscopy (NIR; Hall et al. 1996; Vaccari et al. 1994; Macaloney et al. 1994), which has been employed as a 700- to 2,500-nm scan in the antibiotic fermentation at…”
Near-infrared spectroscopy for medical applications: Current status and future perspectives
Sakudo, A. (2016) · Clinica Chimica Acta · doi:10.1016/j.cca.2016.02.009 · Cited by 248
Near Infrared Spectroscopy for Bioprocess Monitoring and Control: Current Status and Future Trends
Scarff, M., Arnold, S. A., Harvey, L. M., & McNeil, B. (2006) · Critical Reviews in Biotechnology · doi:10.1080/07388550500513677 · Cited by 124
Self-citationShaw, A. D., Kaderbhai, N., Jones, A., Woodward, A. M., Goodacre, R., Rowland, J. J., & Kell, D. B. (1999) · Applied Spectroscopy · doi:10.1366/0003702991945777 · Cited by 84
Alison Arnold, S., Matheson, L., Harvey, L. M., & McNeil, B. (2001) · Biotechnology Letters · doi:10.1023/a:1010343828947 · Cited by 20
“which is seen in the raw spectra ( Hall et al. 1996 ) and the chemometric technique of partial least squares (PLS) is used to actually build the models.”
MethodSelf-citation
Metadata
- Authors
- Hall, J. W., McNeil, B., Rollins, M. J., Draper, I., Thompson, B. G., & MacAloney, G.
- Venue
- Applied Spectroscopy
- Publisher
- SAGE Publications
- Published
- 1996-01
- Volume
- 50
- Issue
- 1
- Pages
- 102-108
- ISSN
- 0003-7028 (ISSN-L)
- 1943-3530
- OpenAlex
- W2067815727
- Cited by
- 99
- References
- 0
- FWCI
- 7.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Near-Infrared Spectroscopic Determination of Acetate, Ammonium, Biomass, and Glycerol in an Industrial Escherichia Coli Fermentation. https://app.cochat.ai/papers/10.1366/0003702963906726
- The paper
- Hall, J. W., McNeil, B., Rollins, M. J., Draper, I., Thompson, B. G., & MacAloney, G. (1996). Near-Infrared Spectroscopic Determination of Acetate, Ammonium, Biomass, and Glycerol in an Industrial Escherichia Coli Fermentation. Applied Spectroscopy. https://doi.org/10.1366/0003702963906726
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.