Prototype Raman Spectroscopic Sensor for in Situ Mineral Characterization on Planetary Surfaces
The DOI matches its Crossref record.
Abstract
Raman spectroscopy has the potential to provide definitive identification and detailed characterization of the minerals that comprise rocks and soils on planetary surfaces. We have designed a probe head for Raman spectroscopy that is suitable for use on a spectrometer deployed by a rover or a lander on the surface of a planet such as Mars, the Moon, or an asteroid. The probe head is lightweight, low power, rugged, and simple. It is based on a tiny distributed feedback diode laser and volume holographic components. A protective shell surrounds the probe head and serves as a mechanical stop for the mechanical arm of a planetary rover or lander during placement of the probe head onto the surface of a rock or soil. Pressing the shell against the rough surface of a target rock or soil also places the sampling objective of the probe head in rough focus, and the probe head is designed to be tolerant of focusing errors of ∼5 mm. A breadboard version of the probe head gave spectra of high quality on clean crystals of diamond, sulfur, calcite, quartz, and olivine. The results are qualitatively comparable to those obtained by using a conventional micro-Raman spectrometer on fine-grained travertine and on difficult specimens of basaltic lavas and impactites whose original mineralogy had been altered by reaction with water and air.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Characterization of Laser-Induced Breakdown Spectroscopy (LIBS) for Application to Space Exploration
Knight, A. K., Scherbarth, N. L., Cremers, D. A., & Ferris, M. J. (2000) · Applied Spectroscopy · doi:10.1366/0003702001949591 · Cited by 432
The Raman Laser Spectrometer for the ExoMars Rover Mission to Mars
Rull, F., Maurice, S., Hutchinson, I., Moral, A., Perez, C., Diaz, C., Colombo, M., Belenguer, T., Lopez-Reyes, G., Sansano, A., et al. (2017) · Astrobiology · doi:10.1089/ast.2016.1567 · Cited by 278
White, S. N. (2009) · Chemical Geology · doi:10.1016/j.chemgeo.2008.11.008 · Cited by 273
Raman spectroscopy of Fe-Ti-Cr-oxides, case study: Martian meteorite EETA79001
Wang, A., Kuebler, K. E., Jolliff, B. L., & Haskin, L. A. (2004) · American Mineralogist · doi:10.2138/am-2004-5-601 · Cited by 234
“It is feasible to build a small Raman system as part of an instrument payload for a rover or a lander to carry out on-surface analyses (Wang et al. 1998; Haskin et al. 2001, 2002; Wang et al. 2003).”
BackgroundSelf-citationRaman spectroscopy in astrobiology
Jorge Villar, S. E., & Edwards, H. G. M. (2006) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-005-0029-2 · Cited by 157
Metadata
- Authors
- Wang, A., Haskin, L. A., & Cortez, E.
- Venue
- Applied Spectroscopy
- Publisher
- SAGE Publications
- Published
- 1998-04
- Volume
- 52
- Issue
- 4
- Pages
- 477-487
- ISSN
- 0003-7028 (ISSN-L)
- 1943-3530
- OpenAlex
- W2068202053
- Cited by
- 108
- References
- 0
- FWCI
- 3.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Prototype Raman Spectroscopic Sensor for in Situ Mineral Characterization on Planetary Surfaces. https://app.cochat.ai/papers/10.1366/0003702981943842
- The paper
- Wang, A., Haskin, L. A., & Cortez, E. (1998). Prototype Raman Spectroscopic Sensor for in Situ Mineral Characterization on Planetary Surfaces. Applied Spectroscopy. https://doi.org/10.1366/0003702981943842
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.