CoChat

Recovery of Absorption Spectra from Fourier Transform Infrared (FT-IR) Microspectroscopic Measurements of Intact Spheres

van Dijk, Thomas, Mayerich, David, Carney, P. Scott, Bhargava, Rohit · 2013 · Applied Spectroscopy

The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.

Abstract

An infrared spectrum recorded from a microscopic sample depends on spectral properties of the constituent material as well as on morphology. Many samples or domains within heterogeneous materials can be idealized as spheres, in which both scattering and absorption from the three-dimensional shape affect the recorded spectrum. Spectra recorded from such objects may be altered to such an extent that they bear little resemblance to spectra recorded from the bulk material; there are no methods, however, to reconcile the two from first principles. Here we provide the mathematical description of the optical physics underlying light-spherical sample interaction within an instrument. We use the developed analytical expressions to predict recorded data from spheres using Fourier transform infrared (FT-IR) spectroscopic imaging. Recorded spectra are shown to depend strongly on the size of the sphere as well as the optical arrangement of the instrument. Next, we present theory and experiments demonstrating the recovery of the complex refractive index of the material using data recorded from a sphere. The effects of the sample morphology on the measured spectra can be removed, and using the imaginary part of the index, the shape-independent IR absorption spectrum of the material is recovered.

Overview

Integrity signals

Registry

Crossref · 10.1366/12-06847

Cites

22 of 22 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Show all 22 references

Research works printed but not linked: 1

  1. van de Hulst H.C., 1982, “Licht Scattering by Small Particles”

Cited by

See all 66

Metadata

Authors
van Dijk, T., Mayerich, D., Carney, P. S., & Bhargava, R.
Affiliations
  • Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, IL 61801 USA
  • University of Illinois Urbana-Champaign (US)
Corresponding author
Bhargava, Rohit
Venue
Applied Spectroscopy
Published
2013-05
Volume
67
Issue
5
Pages
546-552
ISSN
  • 0003-7028 (ISSN-L)
  • 1943-3530
OpenAlex
W2003760854
Cited by
55
References
22
Citations by year
2026: 1 · 2025: 4 · 2024: 1 · 2023: 4 · 2022: 3 · 2021: 4 · 2020: 8 · 2019: 5 · 2018: 3 · 2017: 5 · 2016: 6 · 2015: 5 · 2014: 4 · 2013: 2
FWCI
3.44
Type
journal article
Language
en
Open access
closed
Licence
journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
Locations
  • Applied Spectroscopy (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • National Institutes of Health (5r01ca038882-03)
  • National Cancer Institute (R01CA38882)
Topics
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
  • Physical Sciences › Chemistry › Analytical Chemistry › Spectroscopy and Chemometric Analyses
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Near-Field Optical Microscopy
Keywords
FTIR microspectroscopy, infrared spectra, sphere geometry, complex refractive index, spectral recovery, light scattering, heterogeneous materials, sphere size effects, spectral deconvolution
MeSH terms
Microspheres, Models, Theoretical, Molecular Conformation, Particle Size, Polymethacrylic Acids, Scattering, Radiation, Spectroscopy, Fourier Transform Infrared

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Recovery of Absorption Spectra from Fourier Transform Infrared (FT-IR) Microspectroscopic Measurements of Intact Spheres. https://app.cochat.ai/papers/10.1366/12-06847
The paper
van Dijk, T., Mayerich, D., Carney, P. S., & Bhargava, R. (2013). Recovery of Absorption Spectra from Fourier Transform Infrared (FT-IR) Microspectroscopic Measurements of Intact Spheres. Applied Spectroscopy. https://doi.org/10.1366/12-06847

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.