Recovery of Absorption Spectra from Fourier Transform Infrared (FT-IR) Microspectroscopic Measurements of Intact Spheres
The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
An infrared spectrum recorded from a microscopic sample depends on spectral properties of the constituent material as well as on morphology. Many samples or domains within heterogeneous materials can be idealized as spheres, in which both scattering and absorption from the three-dimensional shape affect the recorded spectrum. Spectra recorded from such objects may be altered to such an extent that they bear little resemblance to spectra recorded from the bulk material; there are no methods, however, to reconcile the two from first principles. Here we provide the mathematical description of the optical physics underlying light-spherical sample interaction within an instrument. We use the developed analytical expressions to predict recorded data from spheres using Fourier transform infrared (FT-IR) spectroscopic imaging. Recorded spectra are shown to depend strongly on the size of the sphere as well as the optical arrangement of the instrument. Next, we present theory and experiments demonstrating the recovery of the complex refractive index of the material using data recorded from a sphere. The effects of the sample morphology on the measured spectra can be removed, and using the imaginary part of the index, the shape-independent IR absorption spectrum of the material is recovered.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Joachain, J. C., & Roper, L. D. (1976) · Physics Today · doi:10.1063/1.3024665 · Cited by 956
Wilkin, C. (1976) · Physics Bulletin · doi:10.1088/0031-9112/27/6/043 · Cited by 883
Kramers–Kronig constrained variational analysis of optical spectra
Kuzmenko, A. B. (2005) · Review of Scientific Instruments · doi:10.1063/1.1979470 · Cited by 856
Martens, H., Nielsen, J. P., & Engelsen, S. B. (2003) · Analytical Chemistry · doi:10.1021/ac020194w · Cited by 507
Bassan, P., Byrne, H. J., Bonnier, F., Lee, J., Dumas, P., & Gardner, P. (2009) · The Analyst · doi:10.1039/b904808a · Cited by 316
Levin, I. W., & Bhargava, R. (2005) · Annual Review of Physical Chemistry · doi:10.1146/annurev.physchem.56.092503.141205 · Cited by 300
Self-citationInfrared Spectroscopic Imaging: The Next Generation
Bhargava, R. (2012) · Applied Spectroscopy · doi:10.1366/12-06801 · Cited by 280
Self-citationMohlenhoff, B., Romeo, M., Diem, M., & Wood, B. R. (2005) · Biophysical Journal · doi:10.1529/biophysj.104.057950 · Cited by 236
Das Verhalten von Lichtwellen in der Nähe eines Brennpunktes oder einer Brennlinie
Debye, P. (1909) · Annalen der Physik · doi:10.1002/andp.19093351406 · Cited by 186
Kohler, A., Sulé-Suso, J., Sockalingum, G. D., Tobin, M., Bahrami, F., Yang, Y., Pijanka, J., Dumas, P., Cotte, M., van Pittius, D. G., et al. (2008) · Applied Spectroscopy · doi:10.1366/000370208783759669 · Cited by 179
Conditions for the validity of the Debye integral representation of focused fields
Wolf, E., & Li, Y. (1981) · Optics Communications · doi:10.1016/0030-4018(81)90107-3 · Cited by 169
Kohler, A., Kirschner, C., Oust, A., & Martens, H. (2005) · Applied Spectroscopy · doi:10.1366/0003702054280649 · Cited by 168
Bassan, P., Kohler, A., Martens, H., Lee, J., Jackson, E., Lockyer, N., Dumas, P., Brown, M., Clarke, N., & Gardner, P. (2010) · Journal of Biophotonics · doi:10.1002/jbio.201000036 · Cited by 134
High-Definition Infrared Spectroscopic Imaging
Reddy, R. K., Walsh, M. J., Schulmerich, M. V., Carney, P. S., & Bhargava, R. (2013) · Applied Spectroscopy · doi:10.1366/11-06568 · Cited by 123
Self-citationTheory of Mid-infrared Absorption Microspectroscopy: II. Heterogeneous Samples
Davis, B. J., Carney, P. S., & Bhargava, R. (2010) · Analytical Chemistry · doi:10.1021/ac902068e · Cited by 117
Self-citationTheory of Midinfrared Absorption Microspectroscopy: I. Homogeneous Samples
Davis, B. J., Carney, P. S., & Bhargava, R. (2010) · Analytical Chemistry · doi:10.1021/ac902067p · Cited by 115
Self-citationBhargava, R., Wang, S.-Q., & Koenig, J. L. (1998) · Applied Spectroscopy · doi:10.1366/0003702981943653 · Cited by 64
Self-citationBhargava, R., Wang, S.-Q., & Koenig, J. L. (1999) · Macromolecules · doi:10.1021/ma9907082 · Cited by 61
Self-citationBhargava, R., Wang, S.-Q., & Koenig, J. L. (1999) · Macromolecules · doi:10.1021/ma990707+ · Cited by 54
Self-citationLee, J., Gazi, E., Dwyer, J., Brown, M. D., Clarke, N. W., Nicholson, J. M., & Gardner, P. (2007) · The Analyst · doi:10.1039/b702064c · Cited by 52
Theory of Infrared Microspectroscopy for Intact Fibers
Davis, B. J., Carney, P. S., & Bhargava, R. (2010) · Analytical Chemistry · doi:10.1021/ac102239b · Cited by 45
Self-citationPlane Wave and Coulomb Asymptotics
Mulligan, P. G., & Crothers, D. S. F. (2004) · Physica Scripta · doi:10.1088/0031-8949/70/1/004 · Cited by 1
Research works printed but not linked: 1
- van de Hulst H.C., 1982, “Licht Scattering by Small Particles”
Cited by
Using Fourier transform IR spectroscopy to analyze biological materials
Baker, M. J., Trevisan, J., Bassan, P., Bhargava, R., Butler, H. J., Dorling, K. M., Fielden, P. R., Fogarty, S. W., Fullwood, N. J., Heys, K. A., et al. (2014) · Nature Protocols · doi:10.1038/nprot.2014.110 · Cited by 1,958
Self-citationThe Bouguer-Beer-Lambert Law: Shining Light on the Obscure
Mayerhöfer, T. G., Pahlow, S., & Popp, J. (2020) · ChemPhysChem · doi:10.1002/cphc.202000464 · Cited by 671
Biomolecular and bioanalytical applications of infrared spectroscopy – A review
Beć, K. B., Grabska, J., & Huck, C. W. (2020) · Analytica Chimica Acta · doi:10.1016/j.aca.2020.04.015 · Cited by 252
Desyatkin, V. G., Martin, W. B., Aliev, A. E., Chapman, N. E., da Fonseca, A. F., Galvao, D. S., Miller, E. R., Stone, K. H., Wang, Z. L., Zakhidov, D., et al. (2022) · Journal of the American Chemical Society · doi:10.1021/jacs.2c06583 · Cited by 196
Emerging Themes in Image Informatics and Molecular Analysis for Digital Pathology
Bhargava, R., & Madabhushi, A. (2016) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-112415-114722 · Cited by 146
Self-citation
Metadata
- Authors
- van Dijk, T., Mayerich, D., Carney, P. S., & Bhargava, R.
- Affiliations
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, IL 61801 USA
- University of Illinois Urbana-Champaign (US)
- Corresponding author
- Bhargava, Rohit
- Venue
- Applied Spectroscopy
- Publisher
- SAGE Publications
- Published
- 2013-05
- Volume
- 67
- Issue
- 5
- Pages
- 546-552
- ISSN
- 0003-7028 (ISSN-L)
- 1943-3530
- OpenAlex
- W2003760854
- Cited by
- 55
- References
- 22
- Citations by year
- 2026: 1 · 2025: 4 · 2024: 1 · 2023: 4 · 2022: 3 · 2021: 4 · 2020: 8 · 2019: 5 · 2018: 3 · 2017: 5 · 2016: 6 · 2015: 5 · 2014: 4 · 2013: 2
- FWCI
- 3.44
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- Applied Spectroscopy (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health (5r01ca038882-03)
- National Cancer Institute (R01CA38882)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
- Physical Sciences › Chemistry › Analytical Chemistry › Spectroscopy and Chemometric Analyses
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Near-Field Optical Microscopy
- Keywords
- FTIR microspectroscopy, infrared spectra, sphere geometry, complex refractive index, spectral recovery, light scattering, heterogeneous materials, sphere size effects, spectral deconvolution
- MeSH terms
- Microspheres, Models, Theoretical, Molecular Conformation, Particle Size, Polymethacrylic Acids, Scattering, Radiation, Spectroscopy, Fourier Transform Infrared
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.