BioAFMviewer: An interactive interface for simulated AFM scanning of biomolecular structures and dynamics
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
We provide a stand-alone software, the BioAFMviewer, which transforms biomolecular structures into the graphical representation corresponding to the outcome of atomic force microscopy (AFM) experiments. The AFM graphics is obtained by performing simulated scanning over the molecular structure encoded in the corresponding PDB file. A versatile molecular viewer integrates the visualization of PDB structures and control over their orientation, while synchronized simulated scanning with variable spatial resolution and tip-shape geometry produces the corresponding AFM graphics. We demonstrate the applicability of the BioAFMviewer by comparing simulated AFM graphics to high-speed AFM observations of proteins. The software can furthermore process molecular movies of conformational motions, e.g. those obtained from servers which model functional transitions within a protein, and produce the corresponding simulated AFM movie. The BioAFMviewer software provides the platform to employ the plethora of structural and dynamical data of proteins in order to help in the interpretation of biomolecular AFM experiments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Protein Data Bank: the single global archive for 3D macromolecular structure data
wwPDB consortium, Burley, S. K., Berman, H. M., Bhikadiya, C., Bi, C., Chen, L., Costanzo, L. D., Christie, C., Duarte, J. M., Dutta, S., et al. (2019) · Nucleic Acids Research · doi:10.1093/nar/gky949 · Cited by 1,163
Cited by
Amyot, R., Miyashita, O., Wu, X., Takeda, K., Kodera, N., Konno, H., Tama, F., & Flechsig, H. (2025) · ACS Nano · doi:10.1021/acsnano.5c10073 · Cited by 13
Self-citationTakeda, K., Flechsig, H., Muro, I., Amyot, R., Kobayashi, F., Kodera, N., Ando, T., & Konno, H. (2023) · Nano Letters · doi:10.1021/acs.nanolett.3c04150 · Cited by 13
Self-citation(2024) · doi:10.3390/a17010038 · Cited by 4
Metadata
- Authors
- Amyot, R., & Flechsig, H.
- Venue
- PLOS Computational Biology
- Publisher
- Public Library of Science (PLoS)
- Published
- 2020-11-18
- Volume
- 16
- Issue
- 11
- Pages
- e1008444
- ISSN
- 1553-734X (ISSN-L)
- 1553-7358
- OpenAlex
- W3106150803
- Cited by
- 85
- References
- 1
- FWCI
- 4.04
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: BioAFMviewer: An interactive interface for simulated AFM scanning of biomolecular structures and dynamics. https://app.cochat.ai/papers/10.1371/journal.pcbi.1008444
- The paper
- Amyot, R., & Flechsig, H. (2020). BioAFMviewer: An interactive interface for simulated AFM scanning of biomolecular structures and dynamics. PLOS Computational Biology. https://doi.org/10.1371/journal.pcbi.1008444
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.