CoChat

Assessing parameter identifiability of a hemodynamics PDE model using spectral surrogates and dimension reduction

Colebank, Mitchel J. · 2025 · PLOS Computational Biology
Cited by 5

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Computational inverse problems for biomedical simulators suffer from limited data and relatively high parameter dimensionality. This often requires sensitivity analysis, where parameters of the model are ranked based on their influence on the specific quantities of interest. This is especially important for simulators used to build medical digital twins, as the amount of data is typically limited. For expensive models, such as blood flow models, emulation is employed to expedite the simulation time. Parameter ranking and fixing using sensitivity analysis are often heuristic, though, and vary with the specific application or simulator used. The present study provides an innovative solution to this problem by leveraging polynomial chaos expansions (PCEs) for both multioutput global sensitivity analysis and formal parameter identifiability. For the former, we use dimension reduction to efficiently quantify time-series sensitivity of a one-dimensional pulmonary hemodynamics model. We consider both Windkessel and Structured Tree boundary conditions. We then use PCEs to construct univariate profile-likelihood confidence intervals and show how changes in experimental design improve identifiability. Our work presents a novel approach to determining parameter identifiability and leverages a common emulation strategy for enabling profile-likelihood analysis in problems governed by partial differential equations.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1371/journal.pcbi.1013553

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Research works printed but not linked: 38

  1. LM Kimpton, 2025, Challenges and opportunities in uncertainty quantification for healthcare and biological systems, Philos Trans A Math Phys Eng Sci, 383, 20240232
  2. MJ Colebank, 2024, Guidelines for mechanistic modeling and analysis in cardiovascular research, American Journal of Physiology-Heart and Circulatory Physiology, 327, 10.1152/ajpheart.00766.2023 · DOI
  3. VG Eck, 2016, A guide to uncertainty quantification and sensitivity analysis for cardiovascular applications, International Journal for Numerical Methods in Biomedical Engineering, 32
  4. Smith RC. Uncertainty quantification: theory, implementation, and applications. 2024. · doi:10.1137/1.9781611977844
  5. E Borgonovo, 2016, Sensitivity analysis: A review of recent advances, European Journal of Operational Research, 248, 869, 10.1016/j.ejor.2015.06.032 · DOI · Paper page
  6. A Alexanderian, 2020, Variance-based sensitivity analysis for time-dependent processes, Reliability Engineering & System Safety, 196, 106722, 10.1016/j.ress.2019.106722 · DOI
  7. JB Nagel, 2020, Principal component analysis and sparse polynomial chaos expansions for global sensitivity analysis and model calibration: Application to urban drainage simulation, Reliability Engineering & System Safety, 195, 106737, 10.1016/j.ress.2019.106737 · DOI
  8. VG Eck, 2017, Effects of arterial wall models and measurement uncertainties on cardiovascular model predictions, J Biomech, 50, 188, 10.1016/j.jbiomech.2016.11.042 · DOI
  9. W Huberts, 2014, Applicability of the polynomial chaos expansion method for personalization of a cardiovascular pulse wave propagation model, Int J Numer Method Biomed Eng, 30, 1679, 10.1002/cnm.2695 · DOI
  10. MJ Colebank, 2024, Efficient uncertainty quantification in a spatially multiscale model of pulmonary arterial and venous hemodynamics, Biomech Model Mechanobiol, 23, 1909, 10.1007/s10237-024-01875-x · DOI
  11. F-G Wieland, 2021, On structural and practical identifiability, Current Opinion in Systems Biology, 25, 60, 10.1016/j.coisb.2021.03.005 · DOI · Paper page
  12. MJ Simpson, 2023, Profile-wise analysis: a profile likelihood-based workflow for identifiability analysis, estimation, and prediction with mechanistic mathematical models, PLoS Comput Biol, 19, 10.1371/journal.pcbi.1011515 · DOI
  13. M Renardy, 2022, Structural identifiability analysis of age-structured PDE epidemic models, J Math Biol, 84, 9, 10.1007/s00285-021-01711-1 · DOI
  14. RJ Murphy, 2024, Implementing measurement error models with mechanistic mathematical models in a likelihood-based framework for estimation, identifiability analysis and prediction in the life sciences, J R Soc Interface, 21, 20230402, 10.1098/rsif.2023.0402 · DOI
  15. M-V Ciocanel, 2024, Parameter identifiability in PDE models of fluorescence recovery after photobleaching, Bulletin of Mathematical Biology, 86, 36, 10.1007/s11538-024-01266-4 · DOI
  16. M Renardy, 2021, To Sobol or not to Sobol? The effects of sampling schemes in systems biology applications., Mathematical biosciences, 108593, 10.1016/j.mbs.2021.108593 · DOI
  17. LM Paun, 2021, Emulation-accelerated Hamiltonian Monte Carlo algorithms for parameter estimation and uncertainty quantification in differential equation models, Stat Comput, 32
  18. R Boiger, 2016, Integration based profile likelihood calculation for PDE constrained parameter estimation problems, Inverse Problems, 32, 125009, 10.1088/0266-5611/32/12/125009 · DOI
  19. MJ Simpson, 2020, Practical parameter identifiability for spatio-temporal models of cell invasion, J R Soc Interface, 17, 20200055, 10.1098/rsif.2020.0055 · DOI
  20. LM Paun, 2025, A comparison of Gaussian processes and polynomial chaos emulators in the context of haemodynamic pulse-wave propagation modelling, Philos Trans A Math Phys Eng Sci, 383, 20240222
  21. MS Olufsen, 2000, Numerical simulation and experimental validation of blood flow in arteries with structured-tree outflow conditions, Annals of Biomedical Engineering, 28, 1281, 10.1114/1.1326031 · DOI · Paper page
  22. J Colebank, 2021, Sensitivity analysis and uncertainty quantification of 1-D models of pulmonary hemodynamics in mice under control and hypertensive conditions, International Journal for Numerical Methods in Biomedical Engineering, 37, 1, 10.1002/cnm.3242 · DOI
  23. LM Paun, 2020, Assessing model mismatch and model selection in a Bayesian uncertainty quantification analysis of a fluid-dynamics model of pulmonary blood circulation, Journal of The Royal Society Interface, 17, 20200886, 10.1098/rsif.2020.0886 · DOI
  24. FN van de Vosse, 2011, Pulse wave propagation in the arterial tree, Annu Rev Fluid Mech, 43, 467, 10.1146/annurev-fluid-122109-160730 · DOI · Paper page
  25. M Qureshi, 2014, Numerical simulation of blood flow and pressure drop in the pulmonary arterial and venous circulation, Biomechanics and Modeling in Mechanobiology, 13, 1137, 10.1007/s10237-014-0563-y · doi:10.1007/s10237-014-0563-y
  26. W Yang, 2019, Evolution of hemodynamic forces in the pulmonary tree with progressively worsening pulmonary arterial hypertension in pediatric patients, Biomech Model Mechanobiol, 18, 779, 10.1007/s10237-018-01114-0 · DOI
  27. N Westerhof, 2009, The arterial windkessel, Medical & Biological Engineering & Computing, 47, 131, 10.1007/s11517-008-0359-2 · DOI · Paper page
  28. MJ Chambers, 2020, Structural and hemodynamic properties of murine pulmonary arterial networks under hypoxia-induced pulmonary hypertension, Proc Inst Mech Eng H, 234, 1312, 10.1177/0954411920944110 · DOI
  29. Marelli S, Sudret B. UQLab: a framework for uncertainty quantification in Matlab. 2014:2554–63. · DOI · Paper page
  30. D Higdon, 2008, Computer model calibration using high-dimensional output, Journal of the American Statistical Association, 103, 570, 10.1198/016214507000000888 · DOI · Paper page
  31. WP Donders, 2015, Personalization of models with many model parameters: an efficient sensitivity analysis approach, Int J Numer Method Biomed Eng, 31, 10.1002/cnm.2727 · DOI
  32. A Melis, 2017, Bayesian sensitivity analysis of a 1D vascular model with Gaussian process emulators, Int J Numer Method Biomed Eng, 33, 10.1002/cnm.2882 · DOI
  33. P Perdikaris, 2015, An effective fractal-tree closure model for simulating blood flow in large arterial networks, Annals of Biomedical Engineering
  34. MS Olufsen, 2012, Rarefaction and blood pressure in systemic and pulmonary arteries, J Fluid Mech, 705, 280, 10.1017/jfm.2012.220 · doi:10.1017/jfm.2012.220
  35. AM Taylor-LaPole, 2025, Parameter selection and optimization of a computational network model of blood flow in single-ventricle patients, Journal of the Royal Society Interface, 22
  36. M Qureshi, 2019, Hemodynamic assessment of pulmonary hypertension in mice: a model-based analysis of the disease mechanism, Biomechanics and Modeling in Mechanobiology, 18, 219, 10.1007/s10237-018-1078-8 · DOI
  37. A Alexanderian, 2021, Optimal experimental design for infinite-dimensional Bayesian inverse problems governed by PDEs: a review, Inverse Problems, 37, 043001, 10.1088/1361-6420/abe10c · DOI
  38. S Conti, 2010, Bayesian emulation of complex multi-output and dynamic computer models, Journal of Statistical Planning and Inference, 140, 640, 10.1016/j.jspi.2009.08.006 · DOI · Paper page

Cited by

See all 5

Metadata

Authors
Colebank, M. J.
Venue
PLOS Computational Biology
Published
2025-10-09
Volume
21
Issue
10
Pages
e1013553
ISSN
1553-7358
Cited by
5
References
2
Language
en

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Assessing parameter identifiability of a hemodynamics PDE model using spectral surrogates and dimension reduction. https://app.cochat.ai/papers/10.1371/journal.pcbi.1013553
The paper
Colebank, M. J. (2025). Assessing parameter identifiability of a hemodynamics PDE model using spectral surrogates and dimension reduction. PLOS Computational Biology. https://doi.org/10.1371/journal.pcbi.1013553

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.