The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Evaluation of a Minimally Invasive Cell Sampling Device Coupled with Assessment of Trefoil Factor 3 Expression for Diagnosing Barrett's Esophagus: A Multi-Center Case–Control Study
Open accessAbstract
BACKGROUND: Barrett's esophagus (BE) is a commonly undiagnosed condition that predisposes to esophageal adenocarcinoma. Routine endoscopic screening for BE is not recommended because of the burden this would impose on the health care system. The objective of this study was to determine whether a novel approach using a minimally invasive cell sampling device, the Cytosponge, coupled with immunohistochemical staining for the biomarker Trefoil Factor 3 (TFF3), could be used to identify patients who warrant endoscopy to diagnose BE. METHODS AND FINDINGS: A case-control study was performed across 11 UK hospitals between July 2011 and December 2013. In total, 1,110 individuals comprising 463 controls with dyspepsia and reflux symptoms and 647 BE cases swallowed a Cytosponge prior to endoscopy. The primary outcome measures were to evaluate the safety, acceptability, and accuracy of the Cytosponge-TFF3 test compared with endoscopy and biopsy. In all, 1,042 (93.9%) patients successfully swallowed the Cytosponge, and no serious adverse events were attributed to the device. The Cytosponge was rated favorably, using a visual analogue scale, compared with endoscopy (p < 0.001), and patients who were not sedated for endoscopy were more likely to rate the Cytosponge higher than endoscopy (Mann-Whitney test, p < 0.001). The overall sensitivity of the test was 79.9% (95% CI 76.4%-83.0%), increasing to 87.2% (95% CI 83.0%-90.6%) for patients with ≥3 cm of circumferential BE, known to confer a higher cancer risk. The sensitivity increased to 89.7% (95% CI 82.3%-94.8%) in 107 patients who swallowed the device twice during the study course. There was no loss of sensitivity in patients with dysplasia. The specificity for diagnosing BE was 92.4% (95% CI 89.5%-94.7%). The case-control design of the study means that the results are not generalizable to a primary care population. Another limitation is that the acceptability data were limited to a single measure. CONCLUSIONS: The Cytosponge-TFF3 test is safe and acceptable, and has accuracy comparable to other screening tests. This test may be a simple and inexpensive approach to identify patients with reflux symptoms who warrant endoscopy to diagnose BE.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
THE USE OF CONFIDENCE OR FIDUCIAL LIMITS ILLUSTRATED IN THE CASE OF THE BINOMIAL
CLOPPER, C. J., & PEARSON, E. S. (1934) · Biometrika · doi:10.1093/biomet/26.4.404 · Cited by 5,003
Tests for Linear Trends in Proportions and Frequencies
Armitage, P. (1955) · Biometrics · doi:10.2307/3001775 · Cited by 2,071
Burden of Gastrointestinal Disease in the United States: 2012 Update
Peery, A. F., Dellon, E. S., Lund, J., Crockett, S. D., McGowan, C. E., Bulsiewicz, W. J., Gangarosa, L. M., Thiny, M. T., Stizenberg, K., Morgan, D. R., et al. (2012) · Gastroenterology · doi:10.1053/j.gastro.2012.08.002 · Cited by 2,015
Multitarget Stool DNA Testing for Colorectal-Cancer Screening
Imperiale, T. F., Ransohoff, D. F., Itzkowitz, S. H., Levin, T. R., Lavin, P., Lidgard, G. P., Ahlquist, D. A., & Berger, B. M. (2014) · New England Journal of Medicine · doi:10.1056/nejmoa1311194 · Cited by 1,900 · cited 1×
“The new multi-target stool DNA test for colorectal cancer screening [30] has an even higher false-positive rate of 10.”
Epidemiology of gastro-oesophageal reflux disease: a systematic review
Dent, J. (2005) · Gut · doi:10.1136/gut.2004.051821 · Cited by 1,887
Radiofrequency Ablation in Barrett's Esophagus with Dysplasia
Shaheen, N. J., Sharma, P., Overholt, B. F., Wolfsen, H. C., Sampliner, R. E., Wang, K. K., Galanko, J. A., Bronner, M. P., Goldblum, J. R., Bennett, A. E., et al. (2009) · New England Journal of Medicine · doi:10.1056/nejmoa0808145 · Cited by 1,438
Incidence of Adenocarcinoma among Patients with Barrett's Esophagus
Hvid-Jensen, F., Pedersen, L., Drewes, A. M., Sørensen, H. T., & Funch-Jensen, P. (2011) · New England Journal of Medicine · doi:10.1056/nejmoa1103042 · Cited by 1,371
Fitzgerald, R. C., di Pietro, M., Ragunath, K., Ang, Y., Kang, J.-Y., Watson, P., Trudgill, N., Patel, P., Kaye, P. V., Sanders, S., et al. (2014) · Gut · doi:10.1136/gutjnl-2013-305372 · Cited by 1,346
Self-citationAmerican Gastroenterological Association Technical Review on the Management of Barrett's Esophagus
Spechler, S. J., Sharma, P., Souza, R. F., Inadomi, J. M., & Shaheen, N. J. (2011) · Gastroenterology · doi:10.1053/j.gastro.2011.01.031 · Cited by 1,060
(2011) · Gastroenterology · doi:10.1053/j.gastro.2011.01.030 · Cited by 1,009
Cited by
Smyth, E. C., Lagergren, J., Fitzgerald, R. C., Lordick, F., Shah, M. A., Lagergren, P., & Cunningham, D. (2017) · Nature Reviews Disease Primers · doi:10.1038/nrdp.2017.48 · Cited by 1,012
Self-citationBanks, M., Graham, D., Jansen, M., Gotoda, T., Coda, S., di Pietro, M., Uedo, N., Bhandari, P., Pritchard, D. M., Kuipers, E. J., et al. (2019) · Gut · doi:10.1136/gutjnl-2018-318126 · Cited by 647
Self-citationDiagnosis and Management of Barrett's Esophagus: An Updated ACG Guideline
Shaheen, N. J., Falk, G. W., Iyer, P. G., Souza, R. F., Yadlapati, R. H., Sauer, B. G., & Wani, S. (2022) · American Journal of Gastroenterology · doi:10.14309/ajg.0000000000001680 · Cited by 510
Fitzgerald, R. C., di Pietro, M., O'Donovan, M., Maroni, R., Muldrew, B., Debiram-Beecham, I., Gehrung, M., Offman, J., Tripathi, M., Smith, S. G., et al. (2020) · The Lancet · doi:10.1016/s0140-6736(20)31099-0 · Cited by 261
Self-citationLett, E., Orji, W. U., & Sebro, R. (2018) · PLOS ONE · doi:10.1371/journal.pone.0207274 · Cited by 260
Metadata
- Authors
- Ross-Innes, C. S., Debiram-Beecham, I., O'Donovan, M., Walker, E., Varghese, S., Lao-Sirieix, P., Lovat, L., Griffin, M., Ragunath, K., Haidry, R., Sami, S. S., Kaye, P., Novelli, M., Disep, B., Ostler, R., Aigret, B., North, B. V., Bhandari, P., Haycock, A., Morris, D., Attwood, S., Dhar, A., Rees, C., Rutter, M. D. D., Sasieni, P. D., Fitzgerald, R. C., & on behalf of the BEST2 Study Group
- Venue
- PLOS Medicine
- Publisher
- Public Library of Science (PLoS)
- Published
- 2015-01-29
- Volume
- 12
- Issue
- 1
- Pages
- e1001780
- ISSN
- 1549-1277 (ISSN-L)
- 1549-1676
- OpenAlex
- W2051570610
- Cited by
- 304
- References
- 29
- FWCI
- 29.69
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluation of a Minimally Invasive Cell Sampling Device Coupled with Assessment of Trefoil Factor 3 Expression for Diagnosing Barrett's Esophagus: A Multi-Center Case–Control Study. https://app.cochat.ai/papers/10.1371/journal.pmed.1001780
- The paper
- Ross-Innes, C. S., Debiram-Beecham, I., O'Donovan, M., Walker, E., Varghese, S., Lao-Sirieix, P., Lovat, L., Griffin, M., Ragunath, K., Haidry, R., Sami, S. S., Kaye, P., Novelli, M., Disep, B., Ostler, R., Aigret, B., North, B. V., Bhandari, P., Haycock, A., . . . on behalf of the BEST2 Study Group. (2015). Evaluation of a Minimally Invasive Cell Sampling Device Coupled with Assessment of Trefoil Factor 3 Expression for Diagnosing Barrett's Esophagus: A Multi-Center Case–Control Study. PLOS Medicine. https://doi.org/10.1371/journal.pmed.1001780
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.