Abstract
BACKGROUND: Atrial fibrillation (AF) is associated with substantial morbidity, in particular stroke. Despite good evidence for the reduction of stroke risk with anticoagulant therapy, there remains significant undertreatment. The main aim of the current study was to investigate whether a clinical decision support tool (CDS) for stroke prevention integrated in the electronic health record could improve adherence to guidelines for stroke prevention in patients with AF. METHODS AND FINDINGS: We conducted a cluster-randomized trial where all 43 primary care clinics in the county of Östergötland, Sweden (population 444,347), were randomized to be part of the CDS intervention or to serve as controls. The CDS produced an alert for physicians responsible for patients with AF and at increased risk for thromboembolism (according to the CHA2DS2-VASc algorithm) without anticoagulant therapy. The primary endpoint was adherence to guidelines after 1 year. After randomization, there were 22 and 21 primary care clinics in the CDS and control groups, respectively. There were no significant differences in baseline adherence to guidelines regarding anticoagulant therapy between the 2 groups (CDS group 70.3% [5,186/7,370; 95% CI 62.9%-77.7%], control group 70.0% [4,187/6,009; 95% CI 60.4%-79.6%], p = 0.83). After 12 months, analysis with linear regression with adjustment for primary care clinic size and adherence to guidelines at baseline revealed a significant increase in guideline adherence in the CDS (73.0%, 95% CI 64.6%-81.4%) versus the control group (71.2%, 95% CI 60.8%-81.6%, p = 0.013, with a treatment effect estimate of 0.016 [95% CI 0.003-0.028]; number of patients with AF included in the final analysis 8,292 and 6,508 in the CDS and control group, respectively). Over the study period, there was no difference in the incidence of stroke, transient ischemic attack, or systemic thromboembolism in the CDS group versus the control group (49 [95% CI 43-55] per 1,000 patients with AF in the CDS group compared to 47 [95% CI 39-55] per 1,000 patients with AF in the control group, p = 0.64). Regarding safety, the CDS group had a lower incidence of significant bleeding, with events in 12 (95% CI 9-15) per 1,000 patients with AF compared to 16 (95% CI 12-20) per 1,000 patients with AF in the control group (p = 0.04). Limitations of the study design include that the analysis was carried out in a catchment area with a high baseline adherence rate, and issues regarding reproducibility to other regions. CONCLUSIONS: The present study demonstrates that a CDS can increase guideline adherence for anticoagulant therapy in patients with AF. Even though the observed difference was small, this is the first randomized study to our knowledge indicating beneficial effects with a CDS in patients with AF. TRIAL REGISTRATION: ClinicalTrials.gov NCT02635685.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intraclass correlations: Uses in assessing rater reliability.
Shrout, P. E., & Fleiss, J. L. (1979) · Psychological Bulletin · doi:10.1037/0033-2909.86.2.420 · Cited by 24,532
Lip, G. Y. H., Nieuwlaat, R., Pisters, R., Lane, D. A., & Crijns, H. J. G. M. (2010) · Chest · doi:10.1378/chest.09-1584 · Cited by 6,879
Hart, R. G., Pearce, L. A., & Aguilar, M. I. (2007) · Annals of Internal Medicine · doi:10.7326/0003-4819-146-12-200706190-00007 · Cited by 4,793
Worldwide Epidemiology of Atrial Fibrillation: A Global Burden of Disease 2010 Study
Chugh, S. S., Havmoeller, R., Narayanan, K., Singh, D., Rienstra, M., Benjamin, E. J., Gillum, R. F., Kim, Y.-H., McAnulty, J. H., Zheng, Z.-J., et al. (2014) · Circulation · doi:10.1161/circulationaha.113.005119 · Cited by 4,506
Kawamoto, K., Houlihan, C. A., Balas, E. A., & Lobach, D. F. (2005) · BMJ · doi:10.1136/bmj.38398.500764.8f · Cited by 2,703
Effect of Clinical Decision-Support Systems: A Systematic Review
Bright, T. J., Wong, A., Dhurjati, R., Bristow, E., Bastian, L., Coeytaux, R. R., Samsa, G., Hasselblad, V., Williams, J. W., Musty, M. D., et al. (2012) · Annals of Internal Medicine · doi:10.7326/0003-4819-157-1-201207030-00450 · Cited by 1,200
Overriding of Drug Safety Alerts in Computerized Physician Order Entry
van der Sijs, H., Aarts, J., Vulto, A., & Berg, M. (2006) · Journal of the American Medical Informatics Association · doi:10.1197/jamia.m1809 · Cited by 1,117
Analysis of cluster randomized trials in primary care: a practical approach
Campbell, M. K., Mollison, J., Steen, N., Grimshaw, J. M., & Eccles, M. (2000) · Family Practice · doi:10.1093/fampra/17.2.192 · Cited by 327
Myers, R. B., Jones, S. L., & Sittig, D. F. (2011) · Applied Clinical Informatics · doi:10.4338/aci-2010-11-ra-0064 · Cited by 67
Kaushal, R., Shojania, K. G., & Bates, D. W. (2003) · Archives of Internal Medicine · doi:10.1001/archinte.163.12.1409 · Cited by 30
Cited by
Hindricks, G., Potpara, T., Dagres, N., Arbelo, E., Bax, J. J., Blomström-Lundqvist, C., Boriani, G., Castella, M., Dan, G.-A., Dilaveris, P. E., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehaa612 · Cited by 9,971
Van Gelder, I. C., Rienstra, M., Bunting, K. V., Casado-Arroyo, R., Caso, V., Crijns, H. J. G. M., De Potter, T. J. R., Dwight, J., Guasti, L., Hanke, T., et al. (2024) · European Heart Journal · doi:10.1093/eurheartj/ehae176 · Cited by 3,024
Joglar, J. A., Chung, M. K., Armbruster, A. L., Benjamin, E. J., Chyou, J. Y., Cronin, E. M., Deswal, A., Eckhardt, L. L., Goldberger, Z. D., Gopinathannair, R., et al. (2024) · Circulation · doi:10.1161/cir.0000000000001193 · Cited by 2,765
2023 ACC/AHA/ACCP/HRS Guideline for the Diagnosis and Management of Atrial Fibrillation
Joglar, J. A., Chung, M. K., Armbruster, A. L., Benjamin, E. J., Chyou, J. Y., Cronin, E. M., Deswal, A., Eckhardt, L. L., Goldberger, Z. D., Gopinathannair, R., et al. (2024) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2023.08.017 · Cited by 933
The effects of on-screen, point of care computer reminders on processes and outcomes of care
Shojania, K. G., Jennings, A., Ramsay, C. R., Grimshaw, J. M., Kwan, J. L., & Lo, L. (2009) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd001096.pub2 · Cited by 466
Kwan, J. L., Lo, L., Ferguson, J., Goldberg, H., Diaz-Martinez, J. P., Tomlinson, G., Grimshaw, J. M., & Shojania, K. G. (2020) · BMJ · doi:10.1136/bmj.m3216 · Cited by 461
Atrial fibrillation: epidemiology, screening and digital health
Linz, D., Gawalko, M., Betz, K., Hendriks, J. M., Lip, G. Y. H., Vinter, N., Guo, Y., & Johnsen, S. (2024) · The Lancet Regional Health - Europe · doi:10.1016/j.lanepe.2023.100786 · Cited by 441
Process mining for healthcare: Characteristics and challenges
Munoz-Gama, J., Martin, N., Fernandez-Llatas, C., Johnson, O. A., Sepúlveda, M., Helm, E., Galvez-Yanjari, V., Rojas, E., Martinez-Millana, A., Aloini, D., et al. (2022) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2022.103994 · Cited by 287
Atasoy, H., Greenwood, B. N., & McCullough, J. S. (2019) · Annual Review of Public Health · doi:10.1146/annurev-publhealth-040218-044206 · Cited by 256
Taheri Moghadam, S., Sadoughi, F., Velayati, F., Ehsanzadeh, S. J., & Poursharif, S. (2021) · BMC Medical Informatics and Decision Making · doi:10.1186/s12911-020-01376-8 · Cited by 136
Lee, T. C., Shah, N. U., Haack, A., & Baxter, S. L. (2020) · Informatics · doi:10.3390/informatics7030025 · Cited by 133
Metadata
- Authors
- Karlsson, L. O., Nilsson, S., Bång, M., Nilsson, L., Charitakis, E., & Janzon, M.
- Venue
- PLOS Medicine
- Publisher
- Public Library of Science (PLoS)
- Published
- 2018-03-13
- Volume
- 15
- Issue
- 3
- Pages
- e1002528
- ISSN
- 1549-1277 (ISSN-L)
- 1549-1676
- OpenAlex
- W2794083991
- Cited by
- 120
- References
- 10
- FWCI
- 8.43
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.