CoChat

Viridot: An automated virus plaque (immunofocus) counter for the measurement of serological neutralizing responses with application to dengue virus

Open access
Katzelnick, Leah C., Coello Escoto, Ana, McElvany, Benjamin D., Chávez, Christian, Salje, Henrik, Luo, Wensheng, Rodriguez-Barraquer, Isabel, Jarman, Richard, Durbin, Anna P., Diehl, Sean A., Smith, Derek J., Whitehead, Stephen S., Cummings, Derek A. T. · 2018 · PLOS Neglected Tropical Diseases
Cited by 127

The DOI matches its Crossref record.

Abstract

The gold-standard method for quantifying neutralizing antibody responses to many viruses, including dengue virus (DENV), is the plaque reduction neutralization test (PRNT, also called the immunofocus reduction neutralization test). The PRNT conducted on 96-well plates is high-throughput and requires a smaller volume of antiserum than on 6- or 24-well plates, but manual plaque counting is challenging and existing automated plaque counters are expensive or difficult to optimize. We have developed Viridot (Viridot package), a program for R with a user interface in shiny, that counts viral plaques of a variety of phenotypes, estimates neutralizing antibody titers, and performs other calculations of use to virologists. The Viridot plaque counter includes an automatic parameter identification mode (misses <10 plaques/well for 87% of diverse DENV strains [n = 1521]) and a mode that allows the user to fine-tune the parameters used for counting plaques. We compared standardized manual and Viridot plaque counting methods applied to the same wells by two analyses and found that Viridot plaque counts were as similar to the same analyst's manual count (Lin's concordance correlation coefficient, ρc = 0.99 [95% confidence interval: 0.99-1.00]) as manual counts between analysts (ρc = 0.99 [95% CI: 0.98-0.99]). The average ratio of neutralizing antibody titers based on manual counted plaques to Viridot counted plaques was 1.05 (95% CI: 0.98-1.14), similar to the average ratio of antibody titers based on manual plaque counts by the two analysts (1.06 [95% CI: 0.84-1.34]). Across diverse DENV and ZIKV strains (n = 14), manual and Viridot plaque counts were mostly consistent (range of ρc = 0.74 to 1.00) and the average ratio of antibody titers based on manual and Viridot counted plaques was close to 1 (0.94 [0.86-1.02]). Thus, Viridot can be used for plaque counting and neutralizing antibody titer estimation of diverse DENV strains and potentially other viruses on 96-well plates as well as for formalization of plaque-counting rules for standardization across experiments and analysts.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1371/journal.pntd.0006862

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 127

Metadata

Authors
Katzelnick, L. C., Coello Escoto, A., McElvany, B. D., Chávez, C., Salje, H., Luo, W., Rodriguez-Barraquer, I., Jarman, R., Durbin, A. P., Diehl, S. A., Smith, D. J., Whitehead, S. S., & Cummings, D. A. T.
Venue
PLOS Neglected Tropical Diseases
Published
2018-10-24
Volume
12
Issue
10
Pages
e0006862
ISSN
  • 1935-2727 (ISSN-L)
  • 1935-2735
OpenAlex
W2898144861
Cited by
127
References
0
FWCI
8.37
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Viridot: An automated virus plaque (immunofocus) counter for the measurement of serological neutralizing responses with application to dengue virus. https://app.cochat.ai/papers/10.1371/journal.pntd.0006862
The paper
Katzelnick, L. C., Coello Escoto, A., McElvany, B. D., Chávez, C., Salje, H., Luo, W., Rodriguez-Barraquer, I., Jarman, R., Durbin, A. P., Diehl, S. A., Smith, D. J., Whitehead, S. S., & Cummings, D. A. T. (2018). Viridot: An automated virus plaque (immunofocus) counter for the measurement of serological neutralizing responses with application to dengue virus. PLOS Neglected Tropical Diseases. https://doi.org/10.1371/journal.pntd.0006862

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.