OBJECTIVE: Recommendations on the frequency of self-monitoring of blood glucose (SMBG) vary widely among physicians treating patients with type 2 diabetes (T2D). Aim of this study was to investigate two testing regimen of SMBG in patients with stable metabolic control. RESEARCH DESIGN AND METHODS: Patients with T2D treated with oral antidiabetic drugs were randomized to two groups: either one SMBG (low) or four SMBG (high) per week. Subjects were followed up after 3, 6 and 12 months. Primary outcome parameter was the change in HbA1c between baseline and 6 months. Primary outcome criterion was tested by a one-sided t- test for non- inferiority. Secondary outcome parameters were safety, compliance and HbA1c at 3 and 12 months. RESULTS: There were no differences in the 202 subjects for demographic and sociodemographic parameters and drug treatment. HbA(1)c (%) at baseline was similar in both groups (7.2+/-1.4 vs. 7.2+/-1.0). Non- inferiority was demonstrated for the low group (p = 0.0022) with a difference from baseline to 6 months of 0.24 in the low and of 0.16 in the high group. Compliance with the testing regimen was 82-90% in both groups. There were no statistical significant differences for compliance, HbA(1)c at 3 and 12 months and serious adverse events (SAE). CONCLUSION: One SMBG per week is as sufficient and safe as four SMBG per week to maintain HbA(1)c in non-insulin treated T2D close to metabolic target. The results of this study are in contrast to current international consensus guidelines. TRIAL REGISTRATION: Controlled-Trials.com ISRCTN79164268.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1371/journal.pone.0003087

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 45

Metadata

Authors
Scherbaum, W. A., Ohmann, C., Abholz, H.-H., Dragano, N., & Lankisch, M.
Venue
PLoS ONE
Published
2008-08-28
Volume
3
Issue
8
Pages
e3087
ISSN
1932-6203 (ISSN-L)
OpenAlex
W2027774191
Cited by
45
References
7
FWCI
4.58
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effect of the Frequency of Self-Monitoring Blood Glucose in Patients with Type 2 Diabetes Treated with Oral Antidiabetic Drugs—A Multi-Centre, Randomized Controlled Trial. https://app.cochat.ai/papers/10.1371/journal.pone.0003087
The paper
Scherbaum, W. A., Ohmann, C., Abholz, H.-H., Dragano, N., & Lankisch, M. (2008). Effect of the Frequency of Self-Monitoring Blood Glucose in Patients with Type 2 Diabetes Treated with Oral Antidiabetic Drugs—A Multi-Centre, Randomized Controlled Trial. PLoS ONE. https://doi.org/10.1371/journal.pone.0003087

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.