CoChat

Real-Time Imaging of HIF-1α Stabilization and Degradation

Open access
Moroz, Ekaterina, Carlin, Sean, Dyomina, Katerina, Burke, Sean, Thaler, Howard T., Blasberg, Ronald, Serganova, Inna · 2009 · PLoS ONE
Cited by 118

The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.

Abstract

HIF-1alpha is overexpressed in many human cancers compared to normal tissues due to the interaction of a multiplicity of factors and pathways that reflect specific genetic alterations and extracellular stimuli. We developed two HIF-1alpha chimeric reporter systems, HIF-1alpha/FLuc and HIF-1alpha(DeltaODDD)/FLuc, to investigate the tightly controlled level of HIF-1alpha protein in normal (NIH3T3 and HEK293) and glioma (U87) cells. These reporter systems provided an opportunity to investigate the degradation of HIF-1alpha in different cell lines, both in culture and in xenografts. Using immunofluorescence microscopy, we observed different patterns of subcellular localization of HIF-1alpha/FLuc fusion protein between normal cells and cancer cells; similar differences were observed for HIF-1alpha in non-transduced, wild-type cells. A dynamic cytoplasmic-nuclear exchange of the fusion protein and HIF-1alpha was observed in NIH3T3 and HEK293 cells under different conditions (normoxia, CoCl2 treatment and hypoxia). In contrast, U87 cells showed a more persistent nuclear localization pattern that was less affected by different growing conditions. Employing a kinetic model for protein degradation, we were able to distinguish two components of HIF-1alpha/FLuc protein degradation and quantify the half-life of HIF-1alpha fusion proteins. The rapid clearance component (t(1/2) approximately 4-6 min) was abolished by the hypoxia-mimetic CoCl2 MG132 treatment and deletion of ODD domain, and reflects the oxygen/VHL-dependent degradation pathway. The slow clearance component (t(1/2) approximately 200 min) is consistent with other unidentified non-oxygen/VHL-dependent degradation pathways. Overall, the continuous bioluminescence readout of HIF-1alpha/FLuc stabilization in vitro and in vivo will facilitate the development and validation of therapeutics that affect the stability and accumulation of HIF-1alpha.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1371/journal.pone.0005077

Cites

20 of 20 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 20 references

Cited by

See all 118

Metadata

Authors
Moroz, E., Carlin, S., Dyomina, K., Burke, S., Thaler, H. T., Blasberg, R., & Serganova, I.
Venue
PLoS ONE
Published
2009-04-04
Volume
4
Issue
4
Pages
e5077
ISSN
1932-6203 (ISSN-L)
OpenAlex
W1972002559
Cited by
118
References
20
FWCI
1.65
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Real-Time Imaging of HIF-1α Stabilization and Degradation. https://app.cochat.ai/papers/10.1371/journal.pone.0005077
The paper
Moroz, E., Carlin, S., Dyomina, K., Burke, S., Thaler, H. T., Blasberg, R., & Serganova, I. (2009). Real-Time Imaging of HIF-1α Stabilization and Degradation. PLoS ONE. https://doi.org/10.1371/journal.pone.0005077

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.