CoChat

From SOMAmer-Based Biomarker Discovery to Diagnostic and Clinical Applications: A SOMAmer-Based, Streamlined Multiplex Proteomic Assay

Open access

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

Abstract

Recently, we reported a SOMAmer-based, highly multiplexed assay for the purpose of biomarker identification. To enable seamless transition from highly multiplexed biomarker discovery assays to a format suitable and convenient for diagnostic and life-science applications, we developed a streamlined, plate-based version of the assay. The plate-based version of the assay is robust, sensitive (sub-picomolar), rapid, can be highly multiplexed (upwards of 60 analytes), and fully automated. We demonstrate that quantification by microarray-based hybridization, Luminex bead-based methods, and qPCR are each compatible with our platform, further expanding the breadth of proteomic applications for a wide user community.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1371/journal.pone.0026332

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 SOMAmer-based assay reagent and assay principles. The primary analyte capture reagent and quantified component consists of an analyte-specific SOMAmer coupled to a Cy3 moiety and a biotin group joined to the fluorophore-substituted SOMAmer through a photocleavable linker (Panel A). The principal features of the assay consist of equilibration of capture reagent and analyte mixture in solution, followed by immobilization of the entire capture reagent population on immobilized streptavidin through the biotin moieties of the capture reagent population. The immobilized capture reagent population, including analyte/capture reagent complexes, is washed to remove non-complexed proteins. Immobilized protein analytes are then biotinylated using a conventional amine-reactive biotinylation reagent. The entire capture reagent population, including biotinylated analyte/capture reagent complexes, is then released into solution via photocleavage. Biotinylated analyte/capture reagent complexes are exclusively captured on immobilized streptavidin via the biotin moieties appended to the analyte population. Washes remove the capture reagent population at large, leaving only analyte/capture reagent complexes. The remaining capture reagent population is a surrogate for the analyte/capture reagent population. This material is eluted from immobilized analytes and quantified via conventional DNA quantification methods.
Figure 1 SOMAmer-based assay reagent and assay principles. The primary analyte capture reagent and quantified component consists of an analyte-specific SOMAmer coupled to a Cy3 moiety and a biotin group joined to the fluorophore-substituted SOMAmer through a photocleavable linker (Panel A). The principal features of the assay consist of equilibration of capture reagent and analyte mixture in solution, followed by immobilization of the entire capture reagent population on immobilized streptavidin through the biotin moieties of the capture reagent population. The immobilized capture reagent population, including analyte/capture reagent complexes, is washed to remove non-complexed proteins. Immobilized protein analytes are then biotinylated using a conventional amine-reactive biotinylation reagent. The entire capture reagent population, including biotinylated analyte/capture reagent complexes, is then released into solution via photocleavage. Biotinylated analyte/capture reagent complexes are exclusively captured on immobilized streptavidin via the biotin moieties appended to the analyte population. Washes remove the capture reagent population at large, leaving only analyte/capture reagent complexes. The remaining capture reagent population is a surrogate for the analyte/capture reagent population. This material is eluted from immobilized analytes and quantified via conventional DNA quantification methods.CC BY · PubMed Central
Figure 2 Diagram of manual plate-based assay steps and dose-response curves generated in manual plate-based assay format. The five steps of the manual plate-based assay - equilibration, biotinylation, photocleavage, and elution, are punctuated by three wash-and-dump cycles and one liquid transfer. The total processing time is about 70 minutes (Panel A). A set of dose response curve generated in a nine-plex manual assay format at various capture reagent concentrations (Panel B). Dose-response curves were generated by spiking analytes into plasma at the indicated concentrations. Shown are resistin and MCP-1. Dose-response curves of MIP-4, RANTES, MMP-9, MMP-7, Lipocalin 2, tPA, and IL-8 can be found in Supporting Materials.
Figure 2 Diagram of manual plate-based assay steps and dose-response curves generated in manual plate-based assay format. The five steps of the manual plate-based assay - equilibration, biotinylation, photocleavage, and elution, are punctuated by three wash-and-dump cycles and one liquid transfer. The total processing time is about 70 minutes (Panel A). A set of dose response curve generated in a nine-plex manual assay format at various capture reagent concentrations (Panel B). Dose-response curves were generated by spiking analytes into plasma at the indicated concentrations. Shown are resistin and MCP-1. Dose-response curves of MIP-4, RANTES, MMP-9, MMP-7, Lipocalin 2, tPA, and IL-8 can be found in Supporting Materials.CC BY · PubMed Central
Figure 3 Precision profiles and limits of quantification of plate- and bead-based assays. Eight individual measurements of fluorescent signal as a function of analyte concentration in buffer were made for each of nine analytes in multiplexed format. For the dose-response curves (left of each panel), the average RFU at each concentration is denoted by the blue markers and the eight individual measurements used to compute each average are denoted by the red markers plotted on the four parameter curve fit (solid blue line). Precision profiles (right of each panel) were computed with two different methods: (1) by calculating the variance in computed concentrations (blue, bottom left of each panel) and (2) by calculating the variance in log RFU (assay response, top right of each panel) combined with the slope of the standard curve (red). Limits of quantification were defined as points on the curves where the coefficient of variation (CV) exceeded 20%. Panels A, C, and E were generated in plate-based format. Panels B, D, and F were generated in bead-based format. Analytes measured were MCP-1 (Panels A and B), MMP9 (Panel C and D), resistin (Panels E and F) tPA (Figure S1B), MMP-7 (Figure S2B), IL-8 (Figure S2A), Lipocalin 2 (Figure S2A), MIP-4 (Figure S2A), Protein S (Figure S2B) and RANTES (Figure S2B).
Figure 3 Precision profiles and limits of quantification of plate- and bead-based assays. Eight individual measurements of fluorescent signal as a function of analyte concentration in buffer were made for each of nine analytes in multiplexed format. For the dose-response curves (left of each panel), the average RFU at each concentration is denoted by the blue markers and the eight individual measurements used to compute each average are denoted by the red markers plotted on the four parameter curve fit (solid blue line). Precision profiles (right of each panel) were computed with two different methods: (1) by calculating the variance in computed concentrations (blue, bottom left of each panel) and (2) by calculating the variance in log RFU (assay response, top right of each panel) combined with the slope of the standard curve (red). Limits of quantification were defined as points on the curves where the coefficient of variation (CV) exceeded 20%. Panels A, C, and E were generated in plate-based format. Panels B, D, and F were generated in bead-based format. Analytes measured were MCP-1 (Panels A and B), MMP9 (Panel C and D), resistin (Panels E and F) tPA (Figure S1B), MMP-7 (Figure S2B), IL-8 (Figure S2A), Lipocalin 2 (Figure S2A), MIP-4 (Figure S2A), Protein S (Figure S2B) and RANTES (Figure S2B).CC BY · PubMed Central
Figure 4 High-resolution titration of analytes. Analytes were titrated in 20% concentration increments in the region of signal generated by serum without spikes. Assay eluates were quantified by Luminex bead hybridization.
Figure 4 High-resolution titration of analytes. Analytes were titrated in 20% concentration increments in the region of signal generated by serum without spikes. Assay eluates were quantified by Luminex bead hybridization.CC BY · PubMed Central
Figure 5 Differential expression between case and control populations. Twenty-four case samples and twenty-four control samples were measured using the model 9-plex plate-based assay. Empirical CDFs were constructed for the control (blue) and case (red) populations separately for each analyte and are displayed in panels a–i. Spikes into the control samples (tPA, MMP-9, and Lipocalin 2) result in clear “down-regulation”, spikes into case samples (IL-8, MCP-1, resistin and RANTES) result in clear “up-regulation” and the two analytes not spiked (MIP-4 and MMP-7) show no differential expression.
Figure 5 Differential expression between case and control populations. Twenty-four case samples and twenty-four control samples were measured using the model 9-plex plate-based assay. Empirical CDFs were constructed for the control (blue) and case (red) populations separately for each analyte and are displayed in panels a–i. Spikes into the control samples (tPA, MMP-9, and Lipocalin 2) result in clear “down-regulation”, spikes into case samples (IL-8, MCP-1, resistin and RANTES) result in clear “up-regulation” and the two analytes not spiked (MIP-4 and MMP-7) show no differential expression.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 11 references

Cited by

See all 324

Metadata

Authors
Kraemer, S., Vaught, J. D., Bock, C., Gold, L., Katilius, E., Keeney, T. R., Kim, N., Saccomano, N. A., Wilcox, S. K., Zichi, D., & Sanders, G. M.
Affiliations
  • SomaLogic (United States) (US)
  • University of Colorado Boulder (US)
Corresponding author
  • Saccomano, Nicholas A.
  • Sanders, Glenn M.
Venue
PLoS ONE
Published
2011-10-17
Volume
6
Issue
10
Pages
e26332
ISSN
1932-6203 (ISSN-L)
OpenAlex
W1976531401
Cited by
310
References
11
Citations by year
2026: 21 · 2025: 23 · 2024: 36 · 2023: 21 · 2022: 37 · 2021: 25 · 2020: 22 · 2019: 16 · 2018: 17 · 2017: 17 · 2016: 17 · 2015: 21 · 2014: 14 · 2013: 7 · 2012: 11
FWCI
4.41
Type
journal article
Language
en
Open access
Locations
  • PLoS ONE (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
  • Figshare (submittedVersion, cc-by)
Topics
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Advanced Biosensing Techniques and Applications
  • Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Advanced biosensing and bioanalysis techniques
Keywords
SOMAmer, biomarker discovery, plate-based assay, microarray hybridization, automated assay, diagnostic applications
MeSH terms
Automation, Biological Assay, Humans, Nucleic Acids, Oligonucleotides, Reproducibility of Results, Biomarkers, Case-Control Studies, Titrimetry, Diagnostic Techniques and Procedures, Proteomics, Limit of Detection

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: From SOMAmer-Based Biomarker Discovery to Diagnostic and Clinical Applications: A SOMAmer-Based, Streamlined Multiplex Proteomic Assay. https://app.cochat.ai/papers/10.1371/journal.pone.0026332
The paper
Kraemer, S., Vaught, J. D., Bock, C., Gold, L., Katilius, E., Keeney, T. R., Kim, N., Saccomano, N. A., Wilcox, S. K., Zichi, D., & Sanders, G. M. (2011). From SOMAmer-Based Biomarker Discovery to Diagnostic and Clinical Applications: A SOMAmer-Based, Streamlined Multiplex Proteomic Assay. PLoS ONE. https://doi.org/10.1371/journal.pone.0026332

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.