The DOI matches its Crossref record; 23 of the 24 references it cites were found in a registry or an index.
Quantification Bias Caused by Plasmid DNA Conformation in Quantitative Real-Time PCR Assay
Open accessAbstract
Quantitative real-time PCR (qPCR) is the gold standard for the quantification of specific nucleic acid sequences. However, a serious concern has been revealed in a recent report: supercoiled plasmid standards cause significant over-estimation in qPCR quantification. In this study, we investigated the effect of plasmid DNA conformation on the quantification of DNA and the efficiency of qPCR. Our results suggest that plasmid DNA conformation has significant impact on the accuracy of absolute quantification by qPCR. DNA standard curves shifted significantly among plasmid standards with different DNA conformations. Moreover, the choice of DNA measurement method and plasmid DNA conformation may also contribute to the measurement error of DNA standard curves. Due to the multiple effects of plasmid DNA conformation on the accuracy of qPCR, efforts should be made to assure the highest consistency of plasmid standards for qPCR. Thus, we suggest that the conformation, preparation, quantification, purification, handling, and storage of standard plasmid DNA should be described and defined in the Minimum Information for Publication of Quantitative Real-Time PCR Experiments (MIQE) to assure the reproducibility and accuracy of qPCR absolute quantification.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures






Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“spectrophotometric measurements have been shown to often overestimate the amount of DNA.”
From A highly sensitive internally-controlled real-time PCR assay for mycoplasma detection in cell cultures (2020) · cites this paper as [21]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“In developing this assay, we chose not to use a recombinant plasmid as the IC target, as the amplification efficiencies of the IC target and the linear DNA of mycoplasma would be likely to differ [20,21].”
From A highly sensitive internally-controlled real-time PCR assay for mycoplasma detection in cell cultures (2020) · cites this paper as [21]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“The use of circular supercoiled plasmid has also been reported to lead to overestimation in quantitative PCR”
From A highly sensitive internally-controlled real-time PCR assay for mycoplasma detection in cell cultures (2020) · cites this paper as [21]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Molecular Cloning: A Laboratory Manual
Sambrook, J., Fritsch, E., & Maniatis, T. (1989) · UCLA - Biblioteca de Ciencias de la Salud · Cited by 133,589
Molecular Cloning. A Laboratory Manual
Wood, E. (1983) · Biochemical Education · doi:10.1016/0307-4412(83)90068-7 · Cited by 29,533
Heid, C. A., Stevens, J., Livak, K. J., & Williams, P. M. (1996) · Genome Research · doi:10.1101/gr.6.10.986 · Cited by 6,174
A simple, rapid, and sensitive DNA assay procedure
Labarca, C., & Paigen, K. (1980) · Analytical Biochemistry · doi:10.1016/0003-2697(80)90165-7 · Cited by 4,901
Real-Time PCR for mRNA Quantitation
Wong, M. L., & Medrano, J. F. (2005) · BioTechniques · doi:10.2144/05391rv01 · Cited by 1,786
Gene quantification using real-time quantitative PCR
Ginzinger, D. G. (2002) · Experimental Hematology · doi:10.1016/s0301-472x(02)00806-8 · Cited by 1,278
Demeke, T., & Jenkins, G. R. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-009-3150-9 · Cited by 403
Detection of genetically modified organisms in foods
Ahmed, F. E. (2002) · Trends in Biotechnology · doi:10.1016/s0167-7799(01)01920-5 · Cited by 373
PCR technology for screening and quantification of genetically modified organisms (GMOs)
Holst-Jensen, A., Rønning, S. B., Løvseth, A., & Berdal, K. G. (2003) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-003-1767-7 · Cited by 371
Hou, Y., Zhang, H., Miranda, L., & Lin, S. (2010) · PLoS ONE · doi:10.1371/journal.pone.0009545 · Cited by 222
Research works printed but not linked: 1
- 2003, Regulation (EC) No. 1829/2003 and 1830/2003., Off J Eur Union, L268, 1
Cited by
In vivo high-throughput profiling of CRISPR-Cpf1 activity
Kim, H. K., Song, M., Lee, J., Menon, A. V., Jung, S., Kang, Y.-M., Choi, J. W., Woo, E., Koh, H. C., Nam, J.-W., et al. (2017) · Nature Methods · doi:10.1038/nmeth.4104 · Cited by 383
Sun, Z. Z., Yeung, E., Hayes, C. A., Noireaux, V., & Murray, R. M. (2014) · ACS Synthetic Biology · doi:10.1021/sb400131a · Cited by 279
Yoon, Y., Chung, H. J., Wen Di, D. Y., Dodd, M. C., Hur, H.-G., & Lee, Y. (2017) · Water Research · doi:10.1016/j.watres.2017.06.056 · Cited by 265
Ahmed, Y., Lu, J., Yuan, Z., Bond, P. L., & Guo, J. (2020) · Water Research · doi:10.1016/j.watres.2020.115878 · Cited by 192
Ahmed, W., Bivins, A., Bertsch, P. M., Bibby, K., Choi, P. M., Farkas, K., Gyawali, P., Hamilton, K. A., Haramoto, E., Kitajima, M., et al. (2020) · Current Opinion in Environmental Science & Health · doi:10.1016/j.coesh.2020.09.003 · Cited by 169
Metadata
- Authors
- Lin, C.-H., Chen, Y.-C., & Pan, T.-M.
- Affiliations
- National Taiwan University (TW)
- Corresponding author
- Pan, Tzu-Ming
- Venue
- PLoS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2011-12-14
- Volume
- 6
- Issue
- 12
- Pages
- e29101
- ISSN
- 1932-6203 (ISSN-L)
- PMC
- PMC3237602
- OpenAlex
- W2073174343
- Cited by
- 82
- References
- 24
- Citations by year
- 2026: 4 · 2025: 4 · 2024: 6 · 2023: 8 · 2022: 6 · 2021: 10 · 2020: 11 · 2019: 3 · 2018: 1 · 2017: 4 · 2016: 8 · 2015: 5 · 2014: 4 · 2013: 6 · 2012: 2
- FWCI
- 1.56
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Locations
- PLoS ONE (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Molecular Biology Techniques and Applications
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › DNA and Nucleic Acid Chemistry
- Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
- Keywords
- supercoiled plasmid DNA, absolute quantification, calibration curve, measurement error, plasmid DNA preparation, MIQE guidelines, reproducibility
- MeSH terms
- Biological Assay, Calibration, Zea mays, Diamines, DNA, DNA, Superhelical, Nucleic Acid Conformation, Organic Chemicals, Plasmids, Quinolines, Bias, Plants, Genetically Modified, Benzothiazoles, Real-Time Polymerase Chain Reaction
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.