Line-Scanning Particle Image Velocimetry: An Optical Approach for Quantifying a Wide Range of Blood Flow Speeds in Live Animals
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
BACKGROUND: The ability to measure blood velocities is critical for studying vascular development, physiology, and pathology. A key challenge is to quantify a wide range of blood velocities in vessels deep within living specimens with concurrent diffraction-limited resolution imaging of vascular cells. Two-photon laser scanning microscopy (TPLSM) has shown tremendous promise in analyzing blood velocities hundreds of micrometers deep in animals with cellular resolution. However, current analysis of TPLSM-based data is limited to the lower range of blood velocities and is not adequate to study faster velocities in many normal or disease conditions. METHODOLOGY/PRINCIPAL FINDINGS: We developed line-scanning particle image velocimetry (LS-PIV), which used TPLSM data to quantify peak blood velocities up to 84 mm/s in live mice harboring brain arteriovenous malformation, a disease characterized by high flow. With this method, we were able to accurately detect the elevated blood velocities and exaggerated pulsatility along the abnormal vascular network in these animals. LS-PIV robustly analyzed noisy data from vessels as deep as 850 µm below the brain surface. In addition to analyzing in vivo data, we validated the accuracy of LS-PIV up to 800 mm/s using simulations with known velocity and noise parameters. CONCLUSIONS/SIGNIFICANCE: To our knowledge, these blood velocity measurements are the fastest recorded with TPLSM. Partnered with transgenic mice carrying cell-specific fluorescent reporters, LS-PIV will also enable the direct in vivo correlation of cellular, biochemical, and hemodynamic parameters in high flow vascular development and diseases such as atherogenesis, arteriogenesis, and vascular anomalies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kleinfeld, D., Mitra, P. P., Helmchen, F., & Denk, W. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.26.15741 · Cited by 832 · cited 14×
“(TIF) Figure S6 Analyses of in vivo capillary data by LS-PIV and SVD.”
BackgroundMethodInfluentialTwo-photon microscopy in brain tissue: parameters influencing the imaging depth
Oheim, M., Beaurepaire, E., Chaigneau, E., Mertz, J., & Charpak, S. (2001) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(01)00438-1 · Cited by 425 · cited 1×
“and production of extra-focal fluorescence as the imaging plane is positioned deeper into the specimen [22,45].”
BackgroundSchaffer, C. B., Friedman, B., Nishimura, N., Schroeder, L. F., Tsai, P. S., Ebner, F. F., Lyden, P. D., & Kleinfeld, D. (2006) · PLoS Biology · doi:10.1371/journal.pbio.0040022 · Cited by 400
Self-citationNishimura, N., Schaffer, C. B., Friedman, B., Tsai, P. S., Lyden, P. D., & Kleinfeld, D. (2006) · Nature Methods · doi:10.1038/nmeth844 · Cited by 308
Self-citationShih, A. Y., Friedman, B., Drew, P. K., Tsai, P. S., Lyden, P. D., & Kleinfeld, D. (2009) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2008.166 · Cited by 127 · cited 1×
“Prior investigations using TPLSM have generally focused on blood velocities under 10 mm/s, although one study reported analysis up to 35 mm/s [25].”
MethodLimitations of collateral flow after occlusion of a single cortical penetrating arteriole
Nishimura, N., Rosidi, N. L., Iadecola, C., & Schaffer, C. B. (2010) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2010.157 · Cited by 117
Self-citation
Cited by
Pericyte degeneration leads to neurovascular uncoupling and limits oxygen supply to brain
Kisler, K., Nelson, A. R., Rege, S. V., Ramanathan, A., Wang, Y., Ahuja, A., Lazic, D., Tsai, P. S., Zhao, Z., Zhou, Y., et al. (2017) · Nature Neuroscience · doi:10.1038/nn.4489 · Cited by 497
Apoε4 disrupts neurovascular regulation and undermines white matter integrity and cognitive function
Koizumi, K., Hattori, Y., Ahn, S. J., Buendia, I., Ciacciarelli, A., Uekawa, K., Wang, G., Hiller, A., Zhao, L., Voss, H. U., et al. (2018) · Nature Communications · doi:10.1038/s41467-018-06301-2 · Cited by 179
Self-citationNelson, A. R., Sagare, M. A., Wang, Y., Kisler, K., Zhao, Z., & Zlokovic, B. V. (2020) · Frontiers in Aging Neuroscience · doi:10.3389/fnagi.2020.00108 · Cited by 73
“Velocity data were analyzed using a MatLab algorithm as previously described (Kim et al., 2012; Kisler et al., 2018) and then low-pass filtered (1 Hz cut off) and notch filtered (0.”
MethodLi, D., Deng, X., Xu, Z., Wang, D., Xu, G., Zhang, P., Qiu, P., Xie, W., Wang, D., Tang, B. Z., et al. (2023) · Advanced Functional Materials · doi:10.1002/adfm.202303967 · Cited by 63
Precision 1070 nm Ultrafast Laser‐Induced Photothrombosis of Depth‐Targeted Vessels In Vivo
Zhu, L., Wang, M., Fu, P., Liu, Y., Zhang, H., Roe, A. W., & Xi, W. (2023) · Small Methods · doi:10.1002/smtd.202200917 · Cited by 8
Metadata
- Authors
- Kim, T. N., Goodwill, P. W., Chen, Y., Conolly, S. M., Schaffer, C. B., Liepmann, D., & Wang, R. A.
- Venue
- PLoS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2012-06-26
- Volume
- 7
- Issue
- 6
- Pages
- e38590
- ISSN
- 1932-6203 (ISSN-L)
- OpenAlex
- W2054297253
- Cited by
- 122
- References
- 6
- FWCI
- 6.99
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Line-Scanning Particle Image Velocimetry: An Optical Approach for Quantifying a Wide Range of Blood Flow Speeds in Live Animals. https://app.cochat.ai/papers/10.1371/journal.pone.0038590
- The paper
- Kim, T. N., Goodwill, P. W., Chen, Y., Conolly, S. M., Schaffer, C. B., Liepmann, D., & Wang, R. A. (2012). Line-Scanning Particle Image Velocimetry: An Optical Approach for Quantifying a Wide Range of Blood Flow Speeds in Live Animals. PLoS ONE. https://doi.org/10.1371/journal.pone.0038590
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.