Comparison of Conventional Chemotherapy, Stealth Liposomes and Temperature-Sensitive Liposomes in a Mathematical Model
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Various liposomal drug carriers have been developed to overcome short plasma half-life and toxicity related side effects of chemotherapeutic agents. We developed a mathematical model to compare different liposome formulations of doxorubicin (DOX): conventional chemotherapy (Free-DOX), Stealth liposomes (Stealth-DOX), temperature sensitive liposomes (TSL) with intra-vascular triggered release (TSL-i), and TSL with extra-vascular triggered release (TSL-e). All formulations were administered as bolus at a dose of 9 mg/kg. For TSL, we assumed locally triggered release due to hyperthermia for 30 min. Drug concentrations were determined in systemic plasma, aggregate body tissue, cardiac tissue, tumor plasma, tumor interstitial space, and tumor cells. All compartments were assumed perfectly mixed, and represented by ordinary differential equations. Contribution of liposomal extravasation was negligible in the case of TSL-i, but was the major delivery mechanism for Stealth-DOX and for TSL-e. The dominant delivery mechanism for TSL-i was release within the tumor plasma compartment with subsequent tissue- and cell uptake of released DOX. Maximum intracellular tumor drug concentrations for Free-DOX, Stealth-DOX, TSL-i, and TSL-e were 3.4, 0.4, 100.6, and 15.9 µg/g, respectively. TSL-i and TSL-e allowed for high local tumor drug concentrations with reduced systemic exposure compared to Free-DOX. While Stealth-DOX resulted in high tumor tissue concentrations compared to Free-DOX, only a small fraction was bioavailable, resulting in little cellular uptake. Consistent with clinical data, Stealth-DOX resulted in similar tumor intracellular concentrations as Free-DOX, but with reduced systemic exposure. Optimal release time constants for maximum cellular uptake for Stealth-DOX, TSL-e, and TSL-i were 45 min, 11 min, and <3 s, respectively. Optimal release time constants were shorter for MDR cells, with ∼4 min for Stealth-DOX and for TSL-e. Tissue concentrations correlated well quantitatively with a prior in-vivo study. Mathematical models may thus allow optimization of drug delivery systems to achieve a better therapeutic index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Andresen, T. L., Jensen, S. S., & Jørgensen, K. (2005) · Progress in Lipid Research · doi:10.1016/j.plipres.2004.12.001 · Cited by 580 · cited 3×
“Several recent studies show that liposomal encapsulated DOX can overcome some of these negative side effects of unencapsulated DOX, resulting in reduced toxicity but not necessarily higher treatment efficacy [43].”
BackgroundResultInfluentialAhsan, F. (2002) · Journal of Controlled Release · doi:10.1016/s0168-3659(01)00549-1 · Cited by 570 · cited 1×
“While uptake of liposomes by macrophages and subsequent release of DOX is another possible mechanism enhancing tissue concentration [30,31], this mechanism is not considered here.”
Background
Cited by
Tumor targeting via EPR: Strategies to enhance patient responses
Golombek, S. K., May, J.-N., Theek, B., Appold, L., Drude, N., Kiessling, F., & Lammers, T. (2018) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2018.07.007 · Cited by 1,262
State-of-the-art materials for ultrasound-triggered drug delivery
Sirsi, S. R., & Borden, M. A. (2014) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2013.12.010 · Cited by 488
Overchuk, M., & Zheng, G. (2018) · Biomaterials · doi:10.1016/j.biomaterials.2017.10.024 · Cited by 383
Reversal of multidrug resistance by stimuli-responsive drug delivery systems for therapy of tumor
Yin, Q., Shen, J., Zhang, Z., Yu, H., & Li, Y. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2013.04.011 · Cited by 365
Liposome: composition, characterisation, preparation, and recent innovation in clinical applications
Ahmed, K. S., Hussein, S. A., Ali, A. H., Korma, S. A., Lipeng, Q., & Jinghua, C. (2019) · Journal of Drug Targeting · doi:10.1080/1061186x.2018.1527337 · Cited by 294
Lammers, T. (2024) · Advanced Materials · doi:10.1002/adma.202312169 · Cited by 290
Boissenot, T., Bordat, A., Fattal, E., & Tsapis, N. (2016) · Journal of Controlled Release · doi:10.1016/j.jconrel.2016.09.026 · Cited by 264
Hyperthermia and smart drug delivery systems for solid tumor therapy
Seynhaeve, A. L. B., Amin, M., Haemmerich, D., van Rhoon, G. C., & ten Hagen, T. L. M. (2020) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2020.02.004 · Cited by 229
Self-citationEngineered strategies to enhance tumor penetration of drug-loaded nanoparticles
Souri, M., Soltani, M., Moradi Kashkooli, F., & Kiani Shahvandi, M. (2022) · Journal of Controlled Release · doi:10.1016/j.jconrel.2021.11.024 · Cited by 178
Ultrasound-mediated nano drug delivery for treating cancer: Fundamental physics to future directions
Moradi Kashkooli, F., Jakhmola, A., Hornsby, T. K., Tavakkoli, J. (., & Kolios, M. C. (2023) · Journal of Controlled Release · doi:10.1016/j.jconrel.2023.02.009 · Cited by 177
Jin, Y., Liang, X., An, Y., & Dai, Z. (2016) · Bioconjugate Chemistry · doi:10.1021/acs.bioconjchem.6b00603 · Cited by 72
Souri, M., Soltani, M., & Moradi Kashkooli, F. (2021) · Scientific Reports · doi:10.1038/s41598-021-98554-z · Cited by 61
Souri, M., Moradi Kashkooli, F., & Soltani, M. (2022) · Pharmaceutical Research · doi:10.1007/s11095-022-03255-5 · Cited by 44
Metadata
- Authors
- Gasselhuber, A., Dreher, M. R., Rattay, F., Wood, B. J., & Haemmerich, D.
- Venue
- PLoS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2012-10-17
- Volume
- 7
- Issue
- 10
- Pages
- e47453
- ISSN
- 1932-6203 (ISSN-L)
- OpenAlex
- W2152272197
- Cited by
- 99
- References
- 2
- FWCI
- 3.25
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.