Engineering of In Vitro 3D Capillary Beds by Self-Directed Angiogenic Sprouting
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
In recent years, microfluidic systems have been used to study fundamental aspects of angiogenesis through the patterning of single-layered, linear or geometric vascular channels. In vivo, however, capillaries exist in complex, three-dimensional (3D) networks, and angiogenic sprouting occurs with a degree of unpredictability in all x,y,z planes. The ability to generate capillary beds in vitro that can support thick, biological tissues remains a key challenge to the regeneration of vital organs. Here, we report the engineering of 3D capillary beds in an in vitro microfluidic platform that is comprised of a biocompatible collagen I gel supported by a mechanical framework of alginate beads. The engineered vessels have patent lumens, form robust ~1.5 mm capillary networks across the devices, and support the perfusion of 1 µm fluorescent beads through them. In addition, the alginate beads offer a modular method to encapsulate and co-culture cells that either promote angiogenesis or require perfusion for cell viability in engineered tissue constructs. This laboratory-constructed vascular supply may be clinically significant for the engineering of capillary beds and higher order biological tissues in a scalable and modular manner.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Reconstituting organ-level lung functions on a chip
Huh, D., Matthews, B. D., Mammoto, A., Montoya-Zavala, M., Hsin, H. Y., & Ingber, D. E. (2010) · Science · doi:10.1126/science.1188302 · Cited by 4,250 · cited 1×
“Recent advances in cell biology combined with new technologies to manipulate cell behavior have led to a new field where biological systems are miniaturized within microfluidic systems [6,7].”
BackgroundRapid casting of patterned vascular networks for perfusable engineered three-dimensional tissues
Miller, J. S., Stevens, K. R., Yang, M. T., Baker, B. M., Nguyen, D.-H. T., Cohen, D. M., Toro, E., Chen, A. A., Galie, P. A., Yu, X., et al. (2012) · Nature Materials · doi:10.1038/nmat3357 · Cited by 1,917
In vitro microvessels for the study of angiogenesis and thrombosis
Zheng, Y., Chen, J., Craven, M., Choi, N. W., Totorica, S., Diaz-Santana, A., Kermani, P., Hempstead, B., Fischbach-Teschl, C., López, J. A., et al. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1201240109 · Cited by 894
Interstitial flow influences direction of tumor cell migration through competing mechanisms
Polacheck, W. J., Charest, J. L., & Kamm, R. D. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1103581108 · Cited by 509 · cited 1×
“coverslip, with a central gel region flanked by two microfluidic channels supplied by four inlet/outlet ports [20].”
BackgroundSelf-citationFluid forces control endothelial sprouting
Song, J. W., & Munn, L. L. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1105316108 · Cited by 498 · cited 2×
“Researchers have developed microfluidic platforms to study fundamental aspects of angiogenesis and thrombosis in vitro [8,9], such as real-time imaging of anastomoses [10], and the contribution of interstitial pressure to angiogenic sprouting [11].”
BackgroundMethod
Cited by
Engineering of functional, perfusable 3D microvascular networks on a chip
Kim, S., Lee, H., Chung, M., & Jeon, N. L. (2013) · Lab on a Chip · doi:10.1039/c3lc41320a · Cited by 872
Penny, H. L., Sieow, J. L., Adriani, G., Yeap, W. H., See Chi Ee, P., San Luis, B., Lee, B., Lee, T., Mak, S. Y., Ho, Y. S., et al. (2016) · OncoImmunology · doi:10.1080/2162402x.2016.1191731 · Cited by 254
Self-citationControl of Perfusable Microvascular Network Morphology Using a Multiculture Microfluidic System
Whisler, J. A., Chen, M. B., & Kamm, R. D. (2014) · Tissue Engineering Part C: Methods · doi:10.1089/ten.tec.2013.0370 · Cited by 242
“12 Still lacking, however, is a systematic study of the factors controlling the network morphology and the effects of signaling between different cell types.”
Self-citationTumour-on-a-chip: microfluidic models of tumour morphology, growth and microenvironment
Tsai, H.-F., Trubelja, A., Shen, A. Q., & Bao, G. (2017) · Journal of The Royal Society Interface · doi:10.1098/rsif.2017.0137 · Cited by 214
Microfluidics Enabled Bottom-Up Engineering of 3D Vascularized Tumor for Drug Discovery
Agarwal, P., Wang, H., Sun, M., Xu, J., Zhao, S., Liu, Z., Gooch, K. J., Zhao, Y., Lu, X., & He, X. (2017) · ACS Nano · doi:10.1021/acsnano.7b00824 · Cited by 168
Oxygen supply to encapsulated therapeutic cells
Colton, C. K. (2014) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2014.02.007 · Cited by 162
Microfluidic Tumor–Vascular Model to Study Breast Cancer Cell Invasion and Intravasation
Nagaraju, S., Truong, D., Mouneimne, G., & Nikkhah, M. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201701257 · Cited by 147
Applications of tumor chip technology
Hachey, S. J., & Hughes, C. C. W. (2018) · Lab on a Chip · doi:10.1039/c8lc00330k · Cited by 128
Low levels of physiological interstitial flow eliminate morphogen gradients and guide angiogenesis
Shirure, V. S., Lezia, A., Tao, A., Alonzo, L. F., & George, S. C. (2017) · Angiogenesis · doi:10.1007/s10456-017-9559-4 · Cited by 117
Quantification of angiogenic sprouting under different growth factors in a microfluidic platform
Del Amo, C., Borau, C., Gutiérrez, R., Asín, J., & García-Aznar, J. M. (2016) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2015.10.026 · Cited by 32
“in vitro (Chan et al., 2012), anti-angiogenesis drug screening (Kim”
Metadata
- Authors
- Chan, J. M., Zervantonakis, I. K., Rimchala, T., Polacheck, W. J., Whisler, J., & Kamm, R. D.
- Venue
- PLoS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2012-12-04
- Volume
- 7
- Issue
- 12
- Pages
- e50582
- ISSN
- 1932-6203 (ISSN-L)
- OpenAlex
- W1990722372
- Cited by
- 88
- References
- 5
- FWCI
- 4.71
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.